Multiple testing, cumulative radiation dose, and clinical indications in patients undergoing myocardial perfusion
Andrew J Einstein1, Shepard D Weiner, Adam Bernheim
1Department of Medicine, Cardiology Division, Columbia University Medical Center and New York-Presbyterian Hospital, New York, NY 10032, USA. andrew.einstein@columbia.edu
Context:
Myocardial perfusion imaging (MPI) is the single medical test with the highest radiation burden to the US population. Although many patients undergoing MPI receive repeat MPI testing, or additional procedures involving ionizing radiation, no data are available characterizing their total longitudinal radiation burden and relating radiation burden with reasons for testing.
Objectives:
To characterize procedure counts, cumulative estimated effective doses of radiation, and clinical indications for patients undergoing MPI.
Design, Setting, And Patients:
A retrospective cohort study of 1097 consecutive patients undergoing index MPI during the first 100 days of 2006 (January 1-April 10) at Columbia University Medical Center, New York, New York, that evaluated all preceding medical imaging procedures involving ionizing radiation undergone beginning October 1988, and all subsequent procedures through June 2008, at the center.
Main Outcome Measures:
Cumulative estimated effective dose of radiation, number of procedures involving radiation, and indications for testing.
Results:
Patients underwent a median of 15 (interquartile range [IQR], 6-32; mean, 23.9) procedures involving radiation exposure; of which 4 (IQR, 2-8; mean, 6.5) were high-dose procedures (≥3 mSv; ie, 1 year's background radiation), including 1 (IQR, 1-2; mean, 1.8) MPI study per patient. A total of 344 patients (31.4%) received cumulative estimated effective dose from all medical sources of more than 100 mSv. Multiple MPIs were performed in 424 patients (38.6%), for whom cumulative estimated effective dose was 121 mSv (IQR, 81-189; mean, 149 mSv). Men and white patients had higher cumulative estimated effective doses. More than 80% of initial and 90% of repeat MPI examinations were performed in patients with known cardiac disease or symptoms consistent with it.
Conclusion:
In this institution, multiple testing with MPI was common and in many patients associated with high cumulative estimated doses of radiation.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Acute Coronary Syndrome III: Diagnostic Studies
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...