Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Omission of [(15)O]CO scan for PET CMRO(2) examination using (15)O-labelled compounds
Yasuhiro Sasakawa1, Nobuyuki Kudomi, Yuka Yamamoto
1Department of Clinical Radiology, Kagawa University Hospital, 1750-1 Ikenobe, Miki-cho, Kita-gun, Kagawa, 761-0793, Japan. sasakawa@med.kagawa-u.ac.jp
Objective:
CBF, OEF and CMRO(2) provide us important clinical indices and are used for assessing ischemic degree in cerebrovascular disorders. These quantitative images can be measured by PET using (15)O-labelled tracers such as C(15)O, C(15)O(2) and (15)O(2). To reduce the time of scan, one possibility is to omit the use of CBV data. The present study investigated the influence of fixing the CBV to OEF and CMRO(2) values on subjects with and without cerebrovascular disorders.
Methods:
The study consisted of three groups, namely, GROUP-0 (n = 10), GROUP-1 (n = 9), and GROUP-2 (n = 10), corresponding to--without significant disorder, with elevated CBV, and with reduced CBF and elevated OEF, respectively. All subjects received PET examination and using the PET data OEF and CMRO(2) images were computed by fixing CBV and with CBV data. The computed OEF and CMRO(2) values were compared between the methods.
Results:
The OEF and CMRO(2) values obtained by fixing the CBV were around 10% underestimation against that with CBV data. The regression analysis showed that these values were comparable (r = 0.93-0.98, P < 0.001). The simulation showed that fixing of the CBV would not derive significant error in either OEF or CMRO(2) values, when changed from 0 to 0.08 ml/g.
Conclusion:
This study shows the feasibility of fixing the CBV value for computing OEF and CMRO(2) values in the PET examination, suggesting the CO scan could be eliminated.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
09:08Enhancing Efficiency and Radiolabeling Yields of Carbon-11 Radioligands for Clinical Research Using the Loop Method
Published on: December 20, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...