Related Experiment Video
Updated: Jun 6, 2026

Experimental Model of Ligature-Induced Peri-Implantitis in Mice
Published on: May 17, 2024
Three-dimensional measurement of bone loss at implants in patients with periodontal disease
Marcus Kehl1, Katrin Swierkot, Reiner Mengel
1Department of Periodontology, Dental School of Medicine, Philipps University, Marburg, Germany.
Background:
The aim of this prospective study is to evaluate the three-dimensional marginal bone level around implants 5 to 15 years after loading in partially edentulous patients treated for generalized chronic periodontitis (GCP) and generalized aggressive periodontitis (GAgP).
Methods:
Seventeen patients with GCP and 17 patients with GAgP were treated with a total of 119 implants. Patients were examined clinically on a 3-month recall schedule after insertion of the superstructure, and radiographs were taken at fixed intervals. At the end of the observation period, cone-beam computed tomography was used for the analysis of the circumferential three-dimensional bone level (mesial, distal, buccal, and lingual/palatal) and determination of keratinized mucosa thickness (KMT).
Results:
In both groups, a significant bone loss at implants was observed buccally (GAgP group: 4.49 ± 2.93 mm; GCP group: 3.57 ± 2.94 mm) with significantly more average bone loss in patients with GAgP (3.00 ± 1.67 mm) compared to in patients with GCP (2.45 ± 1.08 mm). The lowest values for KMT in both groups were found in the anterior mandible (GAgP group: 0.99 ± 1.13 mm; GCP group: 0.82 ± 0.91 mm). There were significant correlations between clinical parameters and bone loss in mandibles of patients with GAgP.
Conclusions:
The lowest value for KMT in both groups was found in the mandible. Bone loss was observed buccally and was more pronounced in patients with GAgP, with a significant correlation with keratinized mucosa and increased inflammation.