Related Experiment Video
Updated: Jun 6, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Mass transfer mechanism in liquid chromatography columns packed with shell particles: would there be an optimum shell
Fabrice Gritti1, Georges Guiochon
1Department of Chemistry, University of Tennessee, Knoxville, TN 37996-1600, USA.
Abstract:
The mass transfer mechanisms in columns packed with old (55 μm Zipax and 5 μm Poroshell) and recently commercialized shell particles (2.7 μm Halo-C(18) and Kinetex-C(18)) were investigated from a physico-chemical point of view. Combining a model of diffusion in heterogeneous packed beds (effective medium theory) with values of the heights equivalent to a theoretical plate (HETPs derived from the first and second central moments of the elution profiles) and of the peak variances provided by the peak parking method, we demonstrate that columns packed with current shell particles perform better than those packed with fully porous particles in resolving low molecular weight compounds because the eddy diffusion term of the van Deemter equation of the former is markedly smaller. The calculation of eddy diffusion in column beds suggests that the smaller A terms are due to smaller trans-column velocity bias in columns packed with shell particles. We also show that the mass transfer of large molecules (e.g., proteins) is faster when the internal volume accessible to the analyte increases. Therefore, it is suggested that shell particles made of concentric layers with average pore sizes increasing with increasing diameter would provide columns with higher efficiency.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Principles Of Column Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...