Related Experiment Video
Updated: Jun 6, 2026

The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
Hemostasis in anterior supine intermuscular total hip arthroplasty: pilot study comparing standard electrocautery and
Michael J Morris1, Keith R Berend, Adolph V Lombardi
1Joint Implant Surgeons, Inc., New Albany, Ohio, USA.
Abstract:
Previous studies have demonstrated that using a bipolar sealer device for hemostasis in hip and knee arthroplasty results in a decreased blood loss and transfusion requirement. The anterior supine intermuscular total hip arthroplasty is a minimally invasive approach with a faster initial recovery compared with more traditional hip replacement surgery. A retrospective consecutive series of 100 anterior supine total hip arthroplasties performed by one surgeon was reviewed. In the first 50 cases, traditional electrocautery was used. In the second 50 cases, a bipolar sealer device was used. No significant differences with operative times, intraoperative blood loss, postoperative hemoglobin levels, and length of hospitalization were demonstrated between the two groups. There was a lower rate of intraoperative and postoperative transfusions in the bipolar sealer group.