Related Experiment Video
Updated: Jun 6, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Disposable laryngeal tube suction: standard insertion technique versus two modified insertion techniques for patients
Richard Schalk1, Stephan Engel, Dirk Meininger
1J.W. Goethe-University Hospital, Theodor-Stern-Kai 7, D-60590 Frankfurt, Germany.
Objective:
The disposable laryngeal tube suction (LTS-D) is a supraglottic airway device that can be used as an alternative to tracheal tube to provide ventilation. We tested the hypothesis that, with a frontal jaw thrust insertion technique (FIT/JT), the rate of correct placement attempts in patients with a simulated difficult airway by means of a rigid cervical immobilization collar could be significantly increased compared to the standard insertion technique (SIT) recommended by the manufacturer.
Methods:
70 adult patients undergoing trauma surgery under general anaesthesia had an LTS-D inserted, randomly assigned to the SIT or FIT/JT. In the FIT/JT, the operator was standing in front of the patient's head, and forced chin lift to create sufficient retropharyngeal space was performed. The rate of successful tube placements within 180s and with a maximum of two attempts was the main outcome variable. To distinguish between the effects of the frontal approach and the jaw thrust manoeuvre, a third group was studied after completion of the SIT and FIT/JT groups. The standard insertion technique, but with a jaw thrust manoeuvre (SIT/JT), was employed in another 35 consecutive patients.
Results:
Overall placement success was 49% (SIT, 17/35 patients, P<0.001), 91% (SIT/JT, 32/35 patients) and 100% (FIT/JT). The time required for successful insertion was shortest in the FIT/JT group (23±6s), and significantly longer in the SIT/JT (42±29s, P<0.001) and SIT groups (51±29s, P<0.0001).
Conclusion:
In anaesthetised patients with a simulated difficult airway created with a rigid cervical collar, the overall LTS-D placement success was significantly higher when a jaw thrust manoeuvre was performed, regardless of the particular technique used to introduce the LTS-D. Therefore, an intense jaw thrust manoeuvre should be performed whenever an LTS-D is being inserted.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Suctioning II: Procedure
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...