Effect of a standardized quality-improvement protocol on radiation dose in coronary computed tomographic angiography
Troy M LaBounty1, James P Earls, Jonathon Leipsic
1Department of Medicine, Division of Cardiology, Weill Cornell Medical College at New York Presbyterian Hospital, New York, New York, USA. tml9001@med.cornell.edu
Abstract:
Coronary computed tomographic angiography (CCTA) is associated with ionizing radiation, prompting concerns of future cancer risk. Recent studies have reported reduced radiation doses and similar image quality by the selective use of dose reduction techniques, although the clinical penetration of these methods has been limited. In a quality improvement initiative, a comprehensive, standardized radiation dose reduction protocol was implemented, and its effect on radiation dose and image quality was assessed. A total of 449 patients who underwent 64-detector CCTA at 3 centers were prospectively evaluated, and patients were compared before (n = 247) and after (n = 202) the implementation of a standardized body mass index-based and heart rate-based protocol that simultaneously incorporated multiple dose reduction strategies. Median radiation dose decreased from 2.6 mSv (interquartile range 2.0 to 4.2) to 1.3 mSv (interquartile range 0.8 to 1.9) after the implementation of the standardized protocol (p < 0.001). On multivariate analysis, reduction in overall radiation dose was observed by numerous dose reduction techniques, with varying efficacy of dose lowering: prospective (vs retrospective) electrocardiographic gating (-82%), reduced tube voltage (-41% for 100 vs 120 kV), lower tube current (-25% per -100 mA), and reduced overall scan length (-6% per -1 cm) (p < 0.001 for each). No differences were observed between patients before and after the initiation of the protocol for study interpretability (96% vs 96%, p = 0.66). There was an increase in signal-to-noise ratio after implementing the standardized protocol (11 ± 3 vs 12 ± 4, p < 0.01). In conclusion, a quality improvement protocol for CCTA incorporating multiple dose reduction techniques permits significant radiation dose reduction and may improve the safety profile of CCTA.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
08:02Novel Quantification Protocol for Cardiovascular Calcification Progression Using Longitudinal MicroPET/MicroCT Images
Published on: November 15, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...