Objective Nociceptive Assessment in Ventilated ICU Patients: A Feasibility Study Using Pupillometry and the Nociceptive Flexion Reflex
Published on: July 4, 2018
PhysioDoloris: a monitoring device for analgesia / nociception balance evaluation using heart rate variability
R Logier1, M Jeanne, J De Jonckheere
1INSERM CIC-IT 807, University Hospital of Lille, Institut Hippocrate, 2 avenue Oscar Lambret 59037 Lille Cedex, France. rlogier@chru-lille.fr
Abstract:
Continuous Analgesia / Nociception balance evaluation during general anesthesia could be of precious help for the optimization of analgesic drugs delivery, limiting the risk of toxicity due to the use of opioid drugs, limiting the risk of post operative hyper algesia, and, probably, reducing time of recovery after surgical procedure. Heart Rate Variability analysis has been shown in several studies to measure the Autonomic Nervous System tone, which is strongly influenced by anesthetic drugs. Recording RR series during general anesthesia enabled us to observe that the Respiratory Sinus Arrhythmia pattern changed when a surgical stimulation was painful, even though the patient was not conscious. We have previously developed and evaluated a pain / analgesia measurement algorithm based on the magnitude analysis of the respiratory patterns on the RR series. In this paper, we present the development of a monitoring device (PhysioDoloris), based on the previously described technology, giving in real time an Analgesia Nociception Index (ANI) which can be used during general anesthesia in order to give to the anesthetist, a complementary tool for optimized drug delivery.
More Related Videos
09:38Determining Pain Detection and Tolerance Thresholds Using an Integrated, Multi-Modal Pain Task Battery
Published on: April 14, 2016
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...