Related Experiment Video
Updated: Jun 6, 2026

Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
A novel continuous cardiac output monitor based on pulse wave transit time
Yoshihiro Sugo1, Teiji Ukawa, Sunao Takeda
1Nihon Kohden Corp., 1-31-4 Nishi-Ochiai, Shinjuku-ku, Tokyo, Japan. Yoshihiro_Sugo@mb4.nck.co.jp
Abstract:
Monitoring cardiac output (CO) is important for the management of patient circulation in an operation room (OR) or intensive care unit (ICU). We assumed that the change in pulse wave transit time (PWTT) obtained from an electrocardiogram (ECG) and a pulse oximeter wave is correlated with the change in stroke volume (SV), from which CO is derived. The present study reports the verification of this hypothesis using a hemodynamic analysis theory and animal study. PWTT consists of a pre-ejection period (PEP), the pulse transit time through an elasticity artery (T(1)), and the pulse transit time through peripheral resistance arteries (T(2)). We assumed a consistent negative correlation between PWTT and SV under all conditions of varying circulatory dynamics. The equation for calculating SV from PWTT was derived based on the following procedures. 1. Approximating SV using a linear equation of PWTT. 2. The slope and y-intercept of the above equation were determined under consideration of vessel compliance (SV was divided by Pulse Pressure (PP)), animal type, and the inherent relationship between PP and PWTT. Animal study was performed to verify the above-mentioned assumption. The correlation coefficient of PWTT and SV became r = -0.710 (p 〈 0.001), and a good correlation was admitted. It has been confirmed that accurate continuous CO and SV measurement is only possible by monitoring regular clinical parameters (ECG, SpO2, and NIBP).
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Pulse
The pulse serves as a clinical indicator...
Special considerations while measuring pulse