Related Experiment Video
Updated: Jun 6, 2026

Quantifying Fibrillar Collagen Organization with Curvelet Transform-Based Tools
Published on: November 11, 2020
Robust ODF smoothing for accurate estimation of fiber orientation
Somaieh Beladi1, Pubudu N Pathirana, Peter Brotchie
1School of Science and Technology, Deakin University, Australia. sbela@deakin.edu.au
Abstract:
Q-ball imaging was presented as a model free, linear and multimodal diffusion sensitive approach to reconstruct diffusion orientation distribution function (ODF) using diffusion weighted MRI data. The ODFs are widely used to estimate the fiber orientations. However, the smoothness constraint was proposed to achieve a balance between the angular resolution and noise stability for ODF constructs. Different regularization methods were proposed for this purpose. However, these methods are not robust and quite sensitive to the global regularization parameter. Although, numerical methods such as L-curve test are used to define a globally appropriate regularization parameter, it cannot serve as a universal value suitable for all regions of interest. This may result in over smoothing and potentially end up in neglecting an existing fiber population. In this paper, we propose to include an interpolation step prior to the spherical harmonic decomposition. This interpolation based approach is based on Delaunay triangulation provides a reliable, robust and accurate smoothing approach. This method is easy to implement and does not require other numerical methods to define the required parameters. Also, the fiber orientations estimated using this approach are more accurate compared to other common approaches.
Related Concept Videos
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Fibrous Proteins
Classification of Skeletal Muscle Fibers
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Unsymmetric Bending - Angle of Neutral Axis
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal centroidal axes. The...
Confocal Fluorescence Microscopy
