Effect of pressurization methods on the accuracy of wrist blood pressure measurement
Jong Pal Kim1, Sangkon Bae, Youn Ho Kim
1Samsung Advanced Institute of Technology, NongSeo-dong, GiHeung-Gu, YongIn-Si, Korea. jongpalk@samsung.com
Abstract:
In developing a wrist blood pressure monitor of high and reliable accuracy, the effect of different pressurization methods on the accuracy of blood pressure measurement at the wrist using oscillometry is investigated in this paper. 30 volunteers are recruited and blood pressure readings are taken with three different methods of pressurizing the wrist. It was found that measurement of mean arterial pressure (MAP) is more accurate when the wrist is locally compressed directly over the radial artery (-2.6 ± 11.4 mmHg) or with a region of surrounding tissue (10.3 ± 6.0 mmHg) than when the whole wrist is compressed by a conventional, constricting cuff (-11.4 ± 16.4 mmHg). Characteristics of accuracy, however, differ between the two local pressurization methods. While a square airbag that compresses the wrist directly over the radial artery may measure the most accurate MAP on average, the range of errors among individuals is large. Contrarily, measurements taken by pressurizing a region over the radial artery with a bladder are least affected by individual variability. In order to measure blood pressure accurately at the wrist while unbiased by the population-based algorithmic compensation to ensure accuracy among different individuals, therefore, the use of local pressurization method may be the most appropriate.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...