Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
One-Compartment Open Model: Urinary Excretion Data and Determination of k01:11

One-Compartment Open Model: Urinary Excretion Data and Determination of k

The one-compartment open model leverages urinary excretion data to estimate renal clearance, which gauges the kidney's capacity to expel a drug. This method offers several benefits, including directly measuring drug elimination and assessing the kidney's contribution to overall drug clearance. However, this approach has limitations. It assumes sole renal excretion of the drug, which is not true for all drugs. Accurate urinary excretion and plasma drug concentration measurement can also be...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving01:29

Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving

Mechanistic models play a crucial role in algorithms for numerical problem-solving, particularly in nonlinear mixed effects modeling (NMEM). These models aim to minimize specific objective functions by evaluating various parameter estimates, leading to the development of systematic algorithms. In some cases, linearization techniques approximate the model using linear equations.
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis00:59

Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis

Noncompartmental analyses offer an alternative method for describing drug pharmacokinetics without relying on a specific compartmental model. In this approach, the drug's pharmacokinetics are assumed to be linear, with the terminal phase log-linear. This assumption allows for simplified analysis and interpretation of the drug's behavior in the body.
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This relationship...
Kaplan-Meier Approach01:24

Kaplan-Meier Approach

The Kaplan-Meier estimator is a non-parametric method used to estimate the survival function from time-to-event data. In medical research, it is frequently employed to measure the proportion of patients surviving for a certain period after treatment. This estimator is fundamental in analyzing time-to-event data, making it indispensable in clinical trials, epidemiological studies, and reliability engineering. By estimating survival probabilities, researchers can evaluate treatment effectiveness,...
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models01:06

Model Approaches for Pharmacokinetic Data: Distributed Parameter Models

Pharmacokinetic models are mathematical constructs that represent and predict the time course of drug concentrations in the body, providing meaningful pharmacokinetic parameters. These models are categorized into compartment, physiological, and distributed parameter models.
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Image Reconstruction with Maclaurin Series Expansion.

International journal of biomedical research & practice·2026
Same author

A Higher-Order Ising Model with Gradient-Free Update.

Axioms·2026
Same author

Limited-Angle Tomography Using a Neural Network as the Objective Function.

International journal of biomedical research & practice·2026
Same author

Radon Inversion Reconstruction for Kooshball-Like Sampling Trajectory in Cine.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same author

Response to Letter to the Editor.

Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology·2025
Same author

Mitigating the Drawbacks of the L<sub>0</sub> Norm and the Total Variation Norm.

Axioms·2025
Same journal

Effective contrast-enhanced preprocessing for intracranial artery segmentation in digital subtraction angiography.

Physics in medicine and biology·2026
Same journal

Improving Plan Quality in Adaptive Proton Therapy Using an Interactive Dose Modification Tool.

Physics in medicine and biology·2026
Same journal

Technical Note: Real-Time MLC Control and Latency Measurement Optimization with External Verification.

Physics in medicine and biology·2026
Same journal

Fetus-Specific Hematopoietic Stem Cell Dosimetry Framework for Leukemia-Relevant Target Cells During Prenatal Development.

Physics in medicine and biology·2026
Same journal

Deep learning-based dose prediction to enhance planning efficiency in cervical brachytherapy with hybrid applicators.

Physics in medicine and biology·2026
Same journal

Corrigendum: Referenceless MR thermometry-a comparison of five methods (2017<i>Phys. Med. Biol</i>.<b>62</b>1-16).

Physics in medicine and biology·2026
See all related articles

Related Experiment Video

Updated: Jun 6, 2026

An Introduction to Processing, Fitting, and Interpreting Transient Absorption Data
08:12

An Introduction to Processing, Fitting, and Interpreting Transient Absorption Data

Published on: February 16, 2024

Closed-form kinetic parameter estimation solution to the truncated data problem.

Gengsheng L Zeng1, Grant T Gullberg, Dan J Kadrmas

  • 1Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology, University of Utah, 729 Arapeen Drive, Salt Lake City, UT 84108, USA. larry@ucair.med.utah.edu

Physics in Medicine and Biology
|November 25, 2010
PubMed
Summary
This summary is machine-generated.

This study introduces a new method for cardiac single photon emission computed tomography (SPECT) to accurately estimate kinetic parameters from truncated projection data, improving image analysis.

More Related Videos

15N CPMG Relaxation Dispersion for the Investigation of Protein Conformational Dynamics on the &#181;s-ms Timescale
08:09

15N CPMG Relaxation Dispersion for the Investigation of Protein Conformational Dynamics on the µs-ms Timescale

Published on: April 19, 2021

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
08:24

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb

Published on: August 30, 2016

Related Experiment Videos

Last Updated: Jun 6, 2026

An Introduction to Processing, Fitting, and Interpreting Transient Absorption Data
08:12

An Introduction to Processing, Fitting, and Interpreting Transient Absorption Data

Published on: February 16, 2024

15N CPMG Relaxation Dispersion for the Investigation of Protein Conformational Dynamics on the &#181;s-ms Timescale
08:09

15N CPMG Relaxation Dispersion for the Investigation of Protein Conformational Dynamics on the µs-ms Timescale

Published on: April 19, 2021

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
08:24

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb

Published on: August 30, 2016

Area of Science:

  • Medical Imaging
  • Nuclear Medicine
  • Biomedical Engineering

Background:

  • Cardiac single photon emission computed tomography (SPECT) systems often truncate background data.
  • Truncated data in SPECT reconstruction leads to biased images and inaccurate kinetic parameter estimation.
  • Accurate kinetic parameter estimation is crucial for diagnosing cardiac conditions.

Purpose of the Study:

  • To develop a closed-form kinetic parameter estimation solution for dynamic emission imaging using SPECT.
  • To create a method that is insensitive to image bias caused by truncated projection data.
  • To address the challenge of inaccurate kinetic parameter estimates in cardiac SPECT.

Main Methods:

  • Developed a closed-form kinetic parameter estimation solution.
  • Incorporated background bias as an estimable parameter.
  • Assumed bias is proportional to truncated activities and background concentration is proportional to myocardial concentration.
  • Verified the method using a single compartment model with computer simulations (noiseless and noisy projections).

Main Results:

  • The proposed solution is insensitive to image bias from truncated projection data.
  • The method accurately estimates kinetic parameters even with background bias.
  • Simulations demonstrated the effectiveness of the closed-form solution.

Conclusions:

  • The developed method provides accurate kinetic parameter estimates in cardiac SPECT despite data truncation.
  • This approach enhances the reliability of quantitative analysis in cardiac SPECT imaging.
  • The method is applicable to various compartment models as long as background activity can be modeled.