Related Experiment Video
Updated: Jun 6, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Stripping voltammetric measurement of trace metal ions using screen-printed carbon and modified carbon paste
Vernon S Somerset1, Lucas H Hernandez, Emmanuel I Iwuoha
1NRE, Council for Scientific and Industrial Research (CSIR), Stellenbosch, South Africa. vsomerset@csir.co.za
Abstract:
Screen-printed carbon electrodes (SPCEs) and carbon paste electrodes (CPEs) were prepared as "mercury-free" electrochemical sensors for the determination of trace metal ions in aqueous solutions. SPCEs were coated with conducting polymer layers of either polyaniline (PANI), or polyaniline-poly(2,2'-dithiodianiline) (PANI-PDTDA). Furthermore, CPEs containing electroactive compounds with reactivity towards metal ions were employed to obtain enhanced selectivity. Optimised experimental conditions for Hg(2+), Pb(2+), Ni(2+) and Cd(2+) determination included the supporting electrolyte concentration, deposition potential (E(d)) and accumulation time (t(acc)). For the modified carbon paste sensors (MCPEs) it was found that -400 mV is an adequate deposition potential and an accumulation time of 120 s was adequate for the determination using the different constructed electrodes. Initial results showed linearity in the examined concentration range between 1 × 10(-9) M and 1 × 10(-6) M using the SPCE/PANI-PDTDA sensor on laboratory prepared standard solutions, while good selectivity for the different metal ions were obtained. Furthermore, the limit of detection (LOD) was determined for each of the sensors and for the SPCE/PANI-PDTDA sensor it was found to be 2.2 × 10(-13) M, while for the SPCE/PANI sensor the LOD was determined to be 8.4 × 10(-11) M. The MCPE sensors also showed good linearity between the concentration range of 1 × 10(-3) to 1 × 10(-9) M. The LOD values for the various MCPE sensors, were found to be Hg(II) - 1.3 × 10(-7) M; Cd(II) - 2.9 × 10(-7) M; Ni(II) - 3.2 × 10(-7) M; and Pb(II) - 1.7 × 10(-7) M for the CPE/PANI-PDTDA sensor. For the CPE/PANI sensor the LOD values were Hg(II) - 1.5 × 10(-5) M; Cd(II) - 8.6 × 10(-7) M; Ni(II) - 9.5 × 10(-7) M; and Pb(II) - 1.3 × 10(-6) M. For the CPE/MBT sensor the LOD values were Hg(II) - 3.8 × 10(-5) M; Cd(II) - 1.4 × 10(-6) M; Ni(II) - 1 × 10(-6) M; and Pb(II) - 6.3 × 10(-5) M. Very low detection was obtained for the SPCE/PANI-PDTDA sensor in Hg(2+) determination, while the MCPE sensors delivered sensitive simultaneous detection for Hg(2+), Pb(2+), Ni(2+) and Cd(2+) metal ions.
More Related Videos
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrodeposition
Electrodeposition can...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...