Related Experiment Video
Updated: Jun 6, 2026

Laser-induced Breakdown Spectroscopy: A New Approach for Nanoparticle's Mapping and Quantification in Organ Tissue
Published on: June 18, 2014
Detection of lead in paint samples synthesized locally using-laser-induced breakdown spectroscopy
Mohammed A Gondal1, Mohamed M Nasr, Mubarak M Ahmed
1Laser Research Group, Physics Department & Center of Excellence in Nanotechnology, King Fahd University of Petroleum & Minerals, Dhahran, Saudi Arabia. magondal@kfupm.edu.sa
Abstract:
A laser-induced breakdown spectroscopy (LIBS) setup was developed to detect lead and other toxic contaminants such as chromium in paint emulsion samples manufactured in Saudi Arabia. The lead concentration detected in these samples was in the 327.2-755.3 ppm range, which is much higher than the safe permissible limit set by Saudi regulatory agencies. Similarly, chromium concentration (98.1-149.5 ppm) was found in high concentrations as well. The results obtained with our LIBS setup are comparable with the sample analysis utilizing a standard technique such as ICP, and our LIBS results are comparable to ICP with in an accuracy limit of 2-4 %.