Related Experiment Video
Updated: Jun 6, 2026

Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
Stopped-flow microarray immunoassay for detection of viable E. coli by use of chemiluminescence flow-through
Veronika Langer1, Reinhard Niessner, Michael Seidel
1Institute of Hydrochemistry and Chair for Analytical Chemistry, Technische Universität München, Marchioninistrasse 17, 81377 München, Germany.
Abstract:
Rapid multiplexed analysis of microorganisms is important in water analysis to control bacterial contamination for health and safety reasons. Direct quantification of bacteria by means of flow-through microarray immunoassays requires new analysis strategies for optimising sensitivity and the analysis time. For bacteria and for particles, hydrodynamic forces and sedimentation are the dominating effects for binding on surfaces in a flow-through system, whereas diffusion is insignificant. Therefore, we have implemented a stop and flow technique for quantification of viable E. coli cells. The method, with alternation of resting volume elements and pumping the elements forward, was more effective than continuous-flow approaches for analysis of bacteria. For quantification of viable E. coli cells, a chemiluminescence sandwich immunoassay test format was performed by means of antibody microarrays and flow-injection-based microarray analysis. Antibodies, which served as selective capture molecules, were immobilised on polymer-modified glass surfaces serving as microarray substrate. For the bacteria recognition step, a second detection antibody was used, forming a sandwich immunoassay at each spot of the microarray. Detection was carried out with a horseradish peroxidase catalysed chemiluminescence reaction. All assay steps were conducted with an automated flow-through chemiluminescence microarray readout system. Living E. coli cells could be detected in 67 min with a detection limit of 4 × 10(5) cells mL(-1). By introduction of the stopped-flow technique and optimisation of interaction time and interaction steps the achieved detection of E. coli was faster and two orders of magnitude more sensitive than with a conventional ELISA technique in microplates.
More Related Videos
06:20Detection of Enterohemorrhagic Escherichia Coli Colonization in Murine Host by Non-invasive In Vivo Bioluminescence System
Published on: April 9, 2018
06:30Using Microtiter Dish Radiolabeling for Multiple In Vivo Measurements Of Escherichia coli (p)ppGpp Followed by Thin Layer Chromatography
Published on: June 4, 2019