Related Experiment Video
Updated: Jun 6, 2026

04:41
Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Proximal tibial fractures: early experience using polyaxial locking-plate technology.
Vassilios S Nikolaou1, Hiang Boon Tan, George Haidukewych
1Academic Department of Trauma & Orthopaedics, School of Medicine, University of Leeds, Leeds, United Kingdom. vassilios.nikolaou@gmail.com
International Orthopaedics
|November 26, 2010
Summary
The polyaxial locked-plate system effectively treated proximal tibial fractures, achieving high union rates and excellent functional outcomes with minimal complications. This fixation method demonstrated stability for various fracture types.
Area of Science:
- Orthopaedic Surgery
- Trauma Management
- Biomedical Engineering
Background:
- Proximal tibial fractures present complex challenges in achieving stable fixation and optimal functional recovery.
- Traditional fixation methods may have limitations in addressing the diverse fracture patterns and anatomical complexities of the proximal tibia.
Purpose of the Study:
- To evaluate the efficacy and safety of a polyaxial locked-plate fixation system in treating proximal tibial fractures.
- To assess functional outcomes, union rates, and complication profiles associated with this fixation system.
Main Methods:
- A prospective study involving 60 patients with proximal tibial fractures treated with a polyaxial locked-plate system.
- Clinical and radiographic data, including fracture classification (OTA 41-A, B, C), fixation techniques, complications, and union, were analyzed.
- Follow-up averaged 14 months, assessing alignment, hardware integrity, and functional scores (Knee Society Score).
Main Results:
- High fracture union rate (all but three fractures) at a mean of 3.2 months.
- No instances of varus collapse due to screw failure, plate fracture, or screw cutout were observed.
- Excellent functional outcomes with a mean Knee Society Score of 91 and a mean functional score of 89 were reported.
- A low complication rate was noted, with one case of lateral joint collapse in a complex fracture pattern.
Conclusions:
- The polyaxial locking-plate system offers stable fixation for both extra-articular and intra-articular proximal tibial fractures.
- This system facilitates good functional recovery and demonstrates a low complication rate in the management of these injuries.