Shape variability of potentials recorded by a single-fiber electrode and its effect on jitter estimation
Javier Rodríguez1, Nonna Alexandrovna Dimitrova, George Vladimirov Dimitrov
1Department of Electrical and Electronical Engineering, Public University of Navarra, Campus de Arrosadía s/n, Pamplona, Spain. javier.rodriguez.falces@gmail.com
Abstract:
Technical problems accompanying the recording of fiber pair potentials introduce certain instability in the peak-to-peak interval (rise-time, RT) of these potentials. This study aims (1) to measure the variability observed in RT of a large number of sets of consecutive potentials recorded by a single-fiber (SF) electrode and (2) to evaluate the effect of such variability on the jitter estimation. Using a SF electrode, 140 sets of consecutive potentials were recorded from the m. tibialis anterior of four healthy subjects. For each set, the rise-time variability (RTV) was calculated as the standard deviation of the RTs of the discharges within that set. The effect of RTV in the estimation of jitter from simulated fiber pairs with controlled values of neuromuscular jitter was analyzed. The RTVs of sets visually assessed as produced by a "single-fiber" were always less than 20 μs, whereas those of "composite" sets were normally higher than 20 μs. We found that the RTV always increased the estimated jitter of fiber pairs. Such increment depended on the amount of neuromuscular jitter. The RTV provides an estimate of the possible error introduced in jitter assessment. This could be important for the diagnosis of mild clinical manifestations of myasthenia gravis, myopathies, and Duchenne dystrophies.
Related Concept Videos
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...
Standard Electrode Potentials
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Action Potentials