Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
Bioreactor Controls-I01:28

Bioreactor Controls-I

Maintaining optimal conditions within fermenters is essential for maximizing microbial productivity and ensuring process efficiency. This lesson focuses on key parameters—temperature, foam, pH, carbon dioxide, oxygen, and pressure—and their precise measurement and control strategies in fermentation systems.Temperature ControlTemperature regulation is critical due to the exothermic nature of many fermentation processes. In small laboratory fermenters, temperature is commonly monitored using...
Laminar Flow01:27

Laminar Flow

Laminar flow represents a smooth, orderly fluid motion where particles move along parallel paths, resulting in minimal mixing between layers. Streamlined particle paths characterize this flow regime and occur under conditions where viscous forces dominate over inertial forces. The distinction between laminar, transitional, and turbulent flow is primarily determined by the Reynolds number, a dimensionless quantity calculated as:
Turbulent Flow: Problem Solving01:09

Turbulent Flow: Problem Solving

Carbonation is a process used to dissolve carbon dioxide gas in a liquid, commonly used in the production of carbonated beverages. Achieving efficient carbonation requires careful control of temperature, pressure, and flow conditions. By adjusting these parameters, carbonation efficiency can be maximized, producing a higher concentration of CO2 in the liquid.
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures enhance...
General External Flow Characteristics01:26

General External Flow Characteristics

The study of external flow is essential for creating structures and objects that interact efficiently and safely with moving fluids, such as air or water. When a body is immersed in a flowing fluid, it experiences two primary forces: drag, which opposes motion along the flow direction, and lift, which acts perpendicular to the flow. The shape, size, and orientation of the object influence these forces.Streamlined and Blunt Bodies in External FlowObjects in fluid flow are classified as...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Acoustofluidic Focusing for High-Throughput and Sensitive Analysis of Shape-Encoded Hydrogel Microparticles in Multiplex Immunoassay.

ACS sensors·2026
Same author

Interpretable Deep Learning for Single-Molecule Nanopore Fingerprinting Using Physics-Guided Preprocessing.

ACS sensors·2026
Same author

MicroRNA spatial profiling for assessing drug efficacy in <i>BRCA1</i> -related triple-negative breast tumors.

bioRxiv : the preprint server for biology·2026
Same author

Amplification-Free and Label-Free Multiplexed Profiling of Extracellular Vesicle-Derived MicroRNA via Micropore Sensing Based on PNA-Functionalized Hydrogel Barcodes.

ACS sensors·2026
Same author

MIDAS: rapid, multiplexed molecular profiling for integrated host-pathogen analysis.

Nature communications·2025
Same author

Temperature-Responsive, Injectable Poly(organophosphazene)-Based Hydrogel Adhesive for One-Step Hemostasis and Wound Closure.

Biomacromolecules·2025
Same journal

Controlled encapsulation and droplet size prediction in two-step microfluidic double emulsions.

Lab on a chip·2026
Same journal

A particulate blood-mimicking fluid with physiological biconcave geometry for microscale hemorheology.

Lab on a chip·2026
Same journal

Multicellular sensor arrays fabricated by capillary stamping for pattern-based odor discrimination.

Lab on a chip·2026
Same journal

A real-time microfluidic surveillance system for multiplex detection of heavy metal contamination in wastewater.

Lab on a chip·2026
Same journal

Vision-guided parallel manipulation of cells with optoelectronic tweezers.

Lab on a chip·2026
Same journal

Review of nanofluidic mass transport systems: engineering through physicochemical fields and interfacial properties.

Lab on a chip·2026
See all related articles

Related Experiment Video

Updated: Jun 6, 2026

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration
08:43

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration

Published on: February 1, 2022

Compressed-air flow control system.

Ki Wan Bong1, Stephen C Chapin, Daniel C Pregibon

  • 1Department of Chemical Engineering, MIT, Cambridge, MA 02139, USA.

Lab on a Chip
|December 1, 2010
PubMed
Summary
This summary is machine-generated.

We developed an affordable compressed-air system for precise microfluidic control. This versatile system enables advanced microparticle synthesis and analysis using continuous and pulsed flow methods.

More Related Videos

A Multilayer Microfluidic Platform for the Conduction of Prolonged Cell-Free Gene Expression
11:23

A Multilayer Microfluidic Platform for the Conduction of Prolonged Cell-Free Gene Expression

Published on: October 6, 2019

Cryogenic Liquid Jets for High Repetition Rate Discovery Science
08:34

Cryogenic Liquid Jets for High Repetition Rate Discovery Science

Published on: May 9, 2020

Related Experiment Videos

Last Updated: Jun 6, 2026

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration
08:43

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration

Published on: February 1, 2022

A Multilayer Microfluidic Platform for the Conduction of Prolonged Cell-Free Gene Expression
11:23

A Multilayer Microfluidic Platform for the Conduction of Prolonged Cell-Free Gene Expression

Published on: October 6, 2019

Cryogenic Liquid Jets for High Repetition Rate Discovery Science
08:34

Cryogenic Liquid Jets for High Repetition Rate Discovery Science

Published on: May 9, 2020

Area of Science:

  • Microfluidics
  • Fluid dynamics
  • Chemical engineering

Background:

  • Microfluidic systems often require precise control over multiple fluid streams.
  • Rapid dynamic response is crucial for many microfluidic applications, including particle synthesis and analysis.
  • Existing control systems can be expensive or complex to assemble.

Purpose of the Study:

  • To present the construction and operation of a novel compressed-air driven flow system.
  • To demonstrate a versatile and cost-effective microfluidic control solution.
  • To explore the system's utility in microparticle synthesis and analysis.

Main Methods:

  • Assembly of a compressed-air driven flow system using inexpensive, readily available parts.
  • Operation of the system for precise control of multiple inlet streams.
  • Application of the system in continuous- and pulsed-flow microfluidic procedures.

Main Results:

  • Successful construction and operation of the compressed-air driven flow system.
  • Demonstration of rapid dynamic response and precise multi-stream control.
  • Validation of the system's utility in microparticle synthesis and analysis.

Conclusions:

  • The developed compressed-air system offers a versatile, cost-effective solution for microfluidic applications.
  • The system provides precise control necessary for advanced microparticle synthesis and analysis.
  • This approach facilitates complex microfluidic procedures using accessible components.