Related Experiment Video
Updated: Jun 6, 2026

A Method for Screening and Validation of Resistant Mutations Against Kinase Inhibitors
Published on: December 7, 2014
BsaXI/RFLP analysis of initial or selectively reamplified PCR product is unreliable in detecting the V617F mutation
G C Shepard1, H L Lawson, G A Hawkins
1Section on Hematology and Oncology, Department of Internal Medicine, Wake Forest University School of Medicine, Winston-Salem, North Carolina 27157, USA.
Introduction:
Laboratory testing for the presence of the V617F mutation in JAK2 has taken on great importance in the diagnosis of myeloproliferative disorders. The availability of a facile detection method would bring this testing into greater clinical use. The polymerase chain reaction coupled with restriction fragment length polymorphisms is such a facile method. BsaXI cleaves the normal sequence but does not cleave the sequence leading to the V617F mutation.
Methods:
We have examined the use of selective PCR reamplification with BsaXI cleavage to enrich the fraction of V617F and compared the assignment of mutation with an established qPCR method.
Results:
We found that BsaXI fails to completely cleave normal sequence PCR product, leading to false positivity, particularly at low mutation levels. We also found that first-round standard PCR introduces new mutations in which subsequent reamplification and digestion cannot distinguish from the V617F mutation.
Conclusion:
This combination of problems effectively combines to render selective reamplification and redigestion unsuitable for detecting low fractions of the V617F mutation.