High-accuracy thermochemistry of atmospherically important fluorinated and chlorinated methane derivatives

József Csontos1, Zoltán Rolik, Sanghamitra Das

  • 1Department of Physical Chemistry and Materials Science, Budapest University of Technology and Economics, Budapest P. O. Box 91, H-1521 Hungary. jcsontos@mail.bme.hu

Related Concept Videos

Radical Halogenation: Thermodynamics01:34

Radical Halogenation: Thermodynamics

The thermodynamic favorability of a reaction is determined by the change in Gibbs free energy (ΔG). ΔG has two components- enthalpy (ΔH) and entropy (ΔS). The entropy component is negligible for alkane halogenation because the number of reactants and product molecules are equal. In this case, the ΔG is governed only by the enthalpy component. The most crucial factor that determines ΔH is the strength of the bonds. ΔH can be determined by comparing the energy between bonds broken and bonds...
Radical Substitution: Halogenation of Alkanes and Alkyl Substituents01:27

Radical Substitution: Halogenation of Alkanes and Alkyl Substituents

In the presence of heat or light, alkanes react with molecular halogens to form alkyl halides by a substitution reaction called radical halogenation. This reaction has three steps: initiation, propagation, and termination, as seen in the radical chlorination of methane to produce methyl chloride.
In the initiation step of the reaction, the chlorine molecule undergoes homolytic cleavage in the presence of light or heat, forming two highly reactive chlorine radicals. Propagation occurs in two...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Mass Spectrometry: Alkyl Halide Fragmentation01:22

Mass Spectrometry: Alkyl Halide Fragmentation

Chlorine isotopes exist as 35Cl and 37Cl in a 3:1 ratio, while bromine isotopes exist as 79Br and 81Br in a 1:1 ratio. The mass spectrum of alkyl halides typically produces two distinct molecular ion peaks, the molecular ion peak, [M], and the molecular ion plus two, [M + 2] peak. The relative heights of these two peaks are proportional to the isotopic abundance ratios of the halide. For example, 2‐chloropropane and 1‐bromopropane display two peaks with relative peak heights in a 3:1 and 1:1...
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
Flame Photometry: Overview01:02

Flame Photometry: Overview

Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...