Related Experiment Video
Updated: Jun 6, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Efficacy of a tool combining guide-wire and stylet for the left ventricular lead positioning
Gabriele Giannola1, Saverio Iacopino, Ernesto Lombardo
1Cardiology Unit, Fondazione Istituto San Raffaele-G. Giglio, Contrada Pietrapollastra-Pisciotto, Cefalù 90015, (PA), Italy. gabrigian@libero.it
Aims:
The left ventricular (LV) lead for cardiac resynchronization therapy (CRT) is usually positioned in the coronary sinus via a stylet-guided or an 'over-the-wire' approach. Recently, a new tool has been developed, the Medtronic Attain Hybrid, that combines guide-wire and stylet features. We assessed its safety and efficacy in comparison with standard tools currently used in clinical practice.
Methods And Results:
Patients undergoing standard CRT device implantation were enrolled in seven Italian centres. In the preliminary phase of the study (Phase I), data were collected during implantation procedures performed with standard tools (three patients per centre). Subsequently, the Attain Hybrid was made available in the centres and data were collected for all consecutive patients undergoing implantation during the following year. A learning phase was considered (Phase II), and the last three patients per centre (Phase III) were used for comparison with Phase I. One hundred and seventeen patients were enrolled: 21 patients in Phase I, 75 in Phase II, and 21 in Phase III. Rates of successful implantation were similar in Phases I and III (95 vs. 100%, P=1.000). The pre-defined target vein was reached in 15 (71%) patients in Phase I and in 21 (100%) patients in Phase III (P=0.021). In 10 (48%) procedures during Phase I, LV lead positioning necessitated switching from guide-wire to stylet; this proportion decreased during Phase III (14%, P=0.043). Mean LV positioning time was 16±7 min in Phase I and 11±6 min in Phase III (P=0.040). No adverse events or lead-related complications were detected on implantation or during a follow-up of 6±4 months.
Conclusion:
The Attain Hybrid is safe and effective. It significantly improves target vein accessibility and reduces procedural time in comparison with conventional tools.
More Related Videos
08:31A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization IV: Nursing Management