Related Experiment Video
Updated: Jun 6, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Synthesis of a new solid-phase extractor and its application to preconcentration and determination of lead in water
Cleber Galvão Novaes1, Juracir Silva Santos, Sérgio Luís Costa Ferreira
1Universidade Federal da Bahia, Instituto de Química, Campus Universitário de Ondina, 40.170-280 Salvador, Bahia, Brazil.
Abstract:
A procedure for preconcentration and determination of lead in water is described. The method is based on the sorption of Pb(II) in a minicolumn packed with a functionalized sorbent and subsequent elution with acidic solution. The determination of lead content in the eluate was carried out using flame atomic absorption spectrometry. The sorbent was prepared by immobilization of the ligand 4-(5'-bromo-2'-thiazolylazo)orcinol on polystyrene-divinylbenzene through an azo spacer. Diazotization and coupling reactions were used for synthesis of the sorbent. Some variables affecting the preconcentration were optimized using a full factorial design. Under optimized conditions, the method presented a detection limit of 0.5 microg/L and enrichment factor of 36 for a sample volume of 25 mL. The accuracy of the method was tested by the determination of lead in a standard reference material (National Institute of Standards and Technology 1643d Fresh Water). The proposed procedure was applied to the determination of lead in samples of natural and drinking waters.
Related Concept Videos
Extraction: Advanced Methods
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Washing, Drying, and Ignition of Precipitates
Precipitation and Co-precipitation
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
High-Performance Liquid Chromatography: Elution Process