Related Experiment Video
Updated: Jun 6, 2026

An Intestine/Liver Microphysiological System for Drug Pharmacokinetic and Toxicological Assessment
Published on: December 3, 2020
The comparative pharmacokinetics of modified-release and immediate-release paracetamol in a simulated overdose model
Angela Chiew1, Peter Day, Chris Salonikas
1Clinical and Experimental Toxicology Unit, Department of Emergency Medicine, Prince of Wales Hospital, Barker Street, Randwick, New South Wales 2031, Australia. a_chiew@hotmail.com
Background:
Panadol Extend (PEx) is an over-the-counter, modified-release formulation of paracetamol. Each 665 mg tablet contains 69% slow-release and 31% immediate-release paracetamol. In simulated human overdose, PEx exhibits lower and later peak serum concentrations and a lower area-under-the-curve (AUC) than comparable doses of immediate-release paracetamol (APAP-IR). The lower AUC might result from incomplete absorption of paracetamol or simultaneous metabolism with absorption.
Objective:
Do differences in pharmacokinetics (PK) between PEx and APAP-IR result from incomplete absorption or simultaneous absorption and metabolism of paracetamol?
Methods:
Cross-over study of 80 mg/kg of PEx or APAP-IR in nine volunteers. Serial plasma paracetamol, glucuronide, sulphate and cysteine metabolite estimates performed over 24 h. Peak plasma concentration (Cmax), AUC((0-∞),) time to peak concentration (Tmax) and elimination half-life (t(1/2) ) were compared.
Results:
PEx exhibited significantly lower paracetamol Cmax (252.33 µmol/L vs 565.56 µmol/L, P= 0.0421), AUC((0-∞)) (2133 µmol/h/L vs 2637 µmol/h/L, P= 0.0004) and delayed Tmax (2.889 h vs 1.389 h, P= 0.0189) than APAP-IR. Sulphate metabolite PK parameters for both preparations, PEx vs APAP-IR, showed similar AUC((0-∞)) (1369 µmol/h/L vs 1089 µmol/h/L), Tmax (3.889 h vs 4.444 h), Cmax (95.889 µmol/L vs 95.889 µmol/L) and t(1/2) (3.895 h vs 3.810 h). Glucuronide metabolite concentrations revealed that PEx produced a lower Cmax (257.44 µmol/L vs 335.22 µmol/L, P= 0.0239) than APAP-IR. All other pharmacokinetic parameters were similar. Cysteine metabolite was not detected.
Conclusion:
There were minor differences between the PK parameters of the two major paracetamol metabolites of these two preparations in simulated overdose. The variability in paracetamol AUC seen between the two preparations in moderate overdose might be explained by concurrent metabolism of paracetamol during slower absorption with PEx.
Related Concept Videos
Modified-Release Drug Delivery Systems: Drug Release Characteristics
Nonlinear Pharmacokinetics: Dependence of Elimination Half-Life and Dose Clearance
A study on guinea pigs examined the...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
Modified-Release Drug Delivery Systems: Bioavailability
Modified-Release Drug Delivery Systems: Overview
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This relationship...