A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Support Vector Machines to improve physiologic hot flash measures: application to the ambulatory setting
Rebecca C Thurston1, Javier Hernandez, Jose M Del Rio
1Department of Psychiatry, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania 15213, USA. thurstonrc@upmc.edu
Support Vector Machines (SVMs) offer improved accuracy in classifying physiological hot flashes in midlife women during ambulatory monitoring compared to conventional methods. This advancement enhances the reliability of objective hot flash measurement.
Area of Science:
- Physiology
- Biomedical Engineering
- Women's Health
Background:
- Hot flashes are a common symptom for midlife women, significantly impacting quality of life.
- The conventional physiological criterion for classifying hot flashes (≥2 micromho rise/30 s) demonstrates suboptimal performance.
- Previous laboratory studies showed promise in using Support Vector Machines (SVMs) for improved hot flash classification.
Purpose of the Study:
- To compare the performance of conventional hot flash classification methods with SVM methods in an ambulatory setting.
- To evaluate the accuracy and reliability of objective physiological measures for hot flashes outside the laboratory.
Main Methods:
- Thirty-one women experiencing hot flashes participated in 24-hour ambulatory sternal skin conductance monitoring.
- Hot flashes were quantified using both the conventional criterion (≥2 micromho/30 s) and SVM-based methods.
- Performance metrics including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and F1-score were calculated.
Main Results:
- Conventional methods exhibited low sensitivity (.57) and F1-score (.60), with performance negatively correlated with body mass index (BMI).
- SVM methods significantly improved performance, achieving higher sensitivity (.87) and F1-score (.88), while also reducing the impact of BMI.
- SVMs demonstrated high specificity (.97) and PPV (.90), and excellent NPV (.96) in classifying ambulatory hot flashes.
Conclusions:
- Support Vector Machines (SVMs) provide a more accurate and reliable method for classifying physiological hot flashes in ambulatory settings.
- SVMs overcome limitations of conventional methods, offering improved diagnostic performance irrespective of body mass index.
- This advancement has the potential to enhance objective assessment and management of hot flashes in clinical and research environments.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessment of blood pressure in brachial artery(two-step method)