Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Studies on the emission behavior of polypropylene by gas chromatography/mass spectrometry with static headspace or
E Reingruber1, J Reussner, C Sauer
1Institute of Analytical Chemistry, Johannes Kepler University, Altenbergerstrasse 69, 4040 Linz, Austria. eva.reingruber@jku.at
Abstract:
Emissions from polypropylene (PP) may cause undesired smell, be harmful, or lead to so-called fogging which prohibits its use for car interiors. Thus, qualitative as well as quantitative emission studies are necessary. Thermodesorption (TDS) and static headspace (sHS) with subsequent GC-MS analysis are two powerful tools for analyzing the emission behavior of polymers with a minimum of sample handling. In this work we investigated the emission behavior of PP with TDS and sHS coupled to GC-MS paying special attention to quantitative considerations and to the relevance of emitted substances for fogging phenomena. After extraction for 30min and incubation for 2h, TDS-GC-MS and sHS-GC-MS results were satisfyingly repeatable (with relative standard deviations up to 5%). TDS allowed to introduce substances up to higher boiling points into the GC-MS system, but required to control sample geometry, as emission depended rather on sample surface than on sample mass. In sHS, emission was governed by partitioning between the gas and the sample phase rather than by full evaporation of the analytes. Above a certain analyte-dependent amount, peak area became independent of the sample amount. However, if the sample amount was kept constant, peak areas of emitted substances showed a linear dependence upon concentration of volatiles. Therefore, accurate quantitation was still possible. Typically alkanes, alkenes and dialkenes dominate TDS-GC-MS and sHS-GC-MS chromatograms of PP. They only contributed to fogging if they had a chain length higher than C16. These substances were only detectable when TDS was used for sample introduction, but not with sHS. sHS-GC-MS is thus not useful for judging fogging behavior.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Polymer Classification: Stereospecificity
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...