Related Experiment Video
Updated: Jun 6, 2026

Evaluation of Patients' Posture and Gait Profile After Lumbar Fusion Surgery by Video Rasterstereography and Treadmill Gait Analysis
Published on: March 23, 2019
Walking assessment in people with lumbar spinal stenosis: capacity, performance, and self-report measures
Justin Conway1, Christy C Tomkins, Andrew J Haig
1Department of Physical Medicine and Rehabilitation, University of Michigan, Ann Arbor, MI 48108, USA.
Background Context:
Ambulation limitation is the hallmark of impairment in lumbar spinal stenosis (LSS). Capacity and performance have been defined as two distinct aspects of disability. Previous literature suggests that a person's walking capacity may not be reflected in their daily walking performance.
Purpose:
To examine the relationship between survey instruments, tested walking capacity, and daily ambulatory performance in people diagnosed with LSS.
Study Design/Setting:
Prospective laboratory and clinical observational study at a tertiary care spine clinic.
Patient Sample:
Twelve subjects with LSS significant enough to be scheduled for epidural injection.
Outcome Measures:
Questionnaire (including the Swiss Spinal Stenosis Questionnaire, Pain Disability Index, Oswestry Disability Index, Quebec Back Pain Disability Scale, and 36-Item Short Form Health Survey), laboratory walk testing (walking capacity), and activity monitors (community ambulation).
Methods:
Subjects filled out functional questionnaires, performed a Self-Paced Walking Test (SPWT) of up to 30 minutes, and wore an Actigraph activity monitor during walking hours for 7 days.
Results:
There was no statistically significant relationship between walking capacity (SPWT) and community ambulation per day (activity monitors), however, the maximum time of continuous activity during community ambulation had a strong relationship (r=0.63) with the SPWT. Fifteen self-report measures of ambulation were significantly correlated with the SPWT, activity monitor, or both. Of these, 13 (87%) were more highly correlated to the SPWT than the activity monitor. The SPWT had a strong relationship (r>0.60, p<.05) with global function scales but community ambulation did not.
Conclusions:
Walking capacity and walking performance in LSS appear to be different constructs. Survey instruments appear to reflect capacity rather than performance. This dissociation between walking capacity and walking performance has implications for the clinical management and outcomes assessment of people with LSS.
More Related Videos
06:28Biomechanical Changes Related to Low Back Pain: An Innovative Tool for Movement Pattern Assessment and Treatment Evaluation in Rehabilitation
Published on: December 13, 2024
06:26The Third Channel-Assisted Unilateral Biportal Endoscopic Technique for Lumbar Spinal Stenosis Combined with Contralateral Disc Herniation
Published on: November 17, 2023