Evaporation of ionic liquids at atmospheric pressure: study by ion mobility spectrometry

S Holopainen1, M Nousiainen, J Puton

  • 1Laboratory of Applied Environmental Chemistry, Department of Environmental Science, University of Eastern Finland, Patteristonkatu 1, 50100 Mikkeli, Finland.

Talanta
|December 15, 2010
PubMed

Related Concept Videos

Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Volatilization01:10

Volatilization

Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
Distillation: Vapor–Liquid Equilibria01:01

Distillation: Vapor–Liquid Equilibria

Distillation is a separation technique that takes advantage of the boiling point properties of disparate elements in a mixture. To perform distillation, we begin by heating a miscible mixture of two liquids with a significant difference in boiling points (at least 20°C). As the solution heats up and reaches the bubble point of the more volatile component, some molecules of the more volatile component transition into the gas phase and travel upward into the condenser, which is a glass tube with...
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
Solubility of Ionic Compounds02:55

Solubility of Ionic Compounds

Solubility is the measure of the maximum amount of solute that can be dissolved in a given quantity of solvent at a given temperature and pressure. Solubility is usually measured in molarity (M) or moles per liter (mol/L). A compound is termed soluble if it dissolves in water.
Transport Number01:31

Transport Number

The transport number is the fraction of the total current carried by an ion in an electrolyte solution. It is defined as the ratio of the current carried by a specific ion to the total current flowing through the solution. The transport number, t, is central to understanding ionic mobility, which describes how fast an ion moves under the influence of an electric field. This link connects the physical behavior of ions in solution to the chemical processes that occur during electrochemical...