Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Dose Size and Dosing Frequency: Determination Methods01:21

Dose Size and Dosing Frequency: Determination Methods

Determining the optimal dose size and dosing frequency in pharmacotherapy is crucial for achieving therapeutic effectiveness while minimizing adverse effects. This article explores the methodologies employed in determining these parameters, focusing on their significance and interplay to tailor dosing regimens.Dose Size: Dose size refers to the amount of a drug administered in a single dose. It is determined based on the drug's pharmacodynamics and pharmacokinetics properties and...
Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses01:25

Determination of Multiple Dosing Parameters: Loading and Maintenance Doses

A loading dose is an essential pharmacological strategy to rapidly achieve the target plasma drug concentration necessary for an immediate therapeutic effect. This approach is especially critical for drugs characterized by slow absorption or extended half-lives, where delaying therapeutic plasma levels could compromise treatment outcomes. By administering a loading dose, clinicians ensure a prompt onset of drug action, even for agents with complex pharmacokinetic profiles.Achieving steady-state...
Maxwell-Boltzmann Distribution: Problem Solving01:20

Maxwell-Boltzmann Distribution: Problem Solving

Individual molecules in a gas move in random directions, but a gas containing numerous molecules has a predictable distribution of molecular speeds, which is known as the Maxwell-Boltzmann distribution, f(v).
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
Radiation: Applications01:17

Radiation: Applications

The average temperature of Earth is the subject of much current discussion. Earth is in radiative contact with both the Sun and dark space; it receives almost all its energy from the radiation of the Sun and reflects some of it into outer space. Dark space is very cold, about 3 K, so Earth radiates energy into it. For instance, heat transfer occurs from soil and grasses, the rate of which can be so rapid that frost can occur on clear summer evenings, even in warm latitudes.
The average...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Functional divergence of duplicated genes results in a novel blast resistance gene Pi50 at the Pi2/9 locus.

TAG. Theoretical and applied genetics. Theoretische und angewandte Genetik·2015
Same author

Regulation of microtubule dynamics by DIAPH3 influences amoeboid tumor cell mechanics and sensitivity to taxanes.

Scientific reports·2015
Same author

Aberrant Functional Connectivity Architecture in Alzheimer's Disease and Mild Cognitive Impairment: A Whole-Brain, Data-Driven Analysis.

BioMed research international·2015
Same author

Alternative NF-κB Isoforms in the Drosophila Neuromuscular Junction and Brain.

PloS one·2015
Same author

Grape seed proanthocyanidin protects liver against ischemia/reperfusion injury by attenuating endoplasmic reticulum stress.

World journal of gastroenterology·2015
Same author

Serum Levels of Progranulin Are Closely Associated with Microvascular Complication in Type 2 Diabetes.

Disease markers·2015
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
Same journal

A novel optical respiratory gating system with a hybrid phase-amplitude algorithm for spot-scanning proton therapy.

Medical physics·2026
Same journal

Gamma Knife treatment planning using knowledge-based reinforcement learning.

Medical physics·2026
Same journal

Development and characterization of a novel, small animal external beam irradiator using a clinical high dose rate brachytherapy source.

Medical physics·2026
Same journal

Deep learning-based dose prediction for MR-guided prostate SIB: Supporting rapid feasibility assessment and adaptive editing margin selection.

Medical physics·2026
See all related articles

Related Experiment Video

Updated: Jun 6, 2026

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
07:57

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform

Published on: March 24, 2022

GPU-accelerated Monte Carlo convolution/superposition implementation for dose calculation.

Bo Zhou1, Cedric X Yu, Danny Z Chen

  • 1Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland 21201, USA. bzhou@umd.edu

Medical Physics
|December 17, 2010
PubMed
Summary
This summary is machine-generated.

This study developed a graphics processing unit (GPU) implementation of the hybrid Monte Carlo convolution/superposition (MCCS) method for radiation therapy dose calculation. The GPU-based MCCS significantly accelerates computation while maintaining accuracy, making it practical for clinical use.

More Related Videos

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
10:33

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation

Published on: September 4, 2017

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

Related Experiment Videos

Last Updated: Jun 6, 2026

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
07:57

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform

Published on: March 24, 2022

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
10:33

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation

Published on: September 4, 2017

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

Area of Science:

  • Medical Physics
  • Computational Science
  • Radiation Oncology

Background:

  • Accurate dose calculation is critical in radiation treatment planning, especially with advanced therapy techniques.
  • Current methods often involve a trade-off between speed (deterministic methods like convolution/superposition) and accuracy (Monte Carlo methods).
  • The hybrid Monte Carlo convolution/superposition (MCCS) method combines strengths but requires optimization for clinical application.

Purpose of the Study:

  • To enhance the performance of the MCCS dose calculation method.
  • To develop a practical, day-to-day radiation therapy planning tool by implementing MCCS on a graphics processing unit (GPU).

Main Methods:

  • Modified the MCCS algorithm to optimize for GPU hardware architecture.
  • Implemented a GPU-based version of the MCCS algorithm.
  • Compared the performance of the GPU implementation against a multithreaded CPU software implementation.

Main Results:

  • Achieved a significant speedup of 6.7-11.4x for clinical cases using the GPU implementation.
  • Demonstrated accuracy comparable to CPU implementation, with less than 2% statistical fluctuation.
  • Validated the feasibility of GPU acceleration for MCCS dose calculations.

Conclusions:

  • GPU implementation offers a feasible and cost-effective solution for accelerating dose calculations compared to clusters or FPGAs.
  • This approach addresses the increasing computational demands for speed and accuracy in radiation therapy.
  • The study also identifies and analyzes inherent limitations of using GPUs for Monte Carlo-type applications.