Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current passing...
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
EDTA: Indirect and Alkalimetric Titration01:23

EDTA: Indirect and Alkalimetric Titration

Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...
Electrodeposition01:08

Electrodeposition

Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Childhood contact with social services, self-harm and suicidal or self-harm ideation in young adulthood: a population-wide record-linkage study.

Epidemiology and psychiatric sciences·2025
Same author

Emergency department presentations with suicide and self-harm ideation: a missed opportunity for intervention?

Epidemiology and psychiatric sciences·2023
Same author

Parental mental health and risk of poor mental health and death by suicide in offspring: a population-wide data-linkage study.

Epidemiology and psychiatric sciences·2022
Same author

Fractional urinary fluoride excretion and nail fluoride concentrations in normal, wasted and stunted 4-5 year-old children in Nepal.

Journal of trace elements in medicine and biology : organ of the Society for Minerals and Trace Elements (GMS)·2021
Same author

EBV-associated primary CNS lymphoma occurring after immunosuppression is a distinct immunobiological entity.

Blood·2020
Same author

Does physical ill-health increase the risk of suicide? A census-based follow-up study of over 1 million people.

Epidemiology and psychiatric sciences·2020

Related Experiment Video

Updated: Jun 6, 2026

TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
09:51

TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples

Published on: September 19, 2025

Development of gold standard ion-selective electrode-based methods for fluoride analysis.

E A Martínez-Mier1, J A Cury, J R Heilman

  • 1Oral Health Research Institute, Indiana University School of Dentistry, Indianapolis, Ind. 46202, USA. esmartin@iupui.edu

Caries Research
|December 17, 2010
PubMed
Summary

Standardized fluoride analysis methods were developed for dental research samples. These new protocols significantly reduced laboratory variations, ensuring more accurate and reliable fluoride concentration measurements.

More Related Videos

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
05:35

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography

Published on: January 17, 2020

Related Experiment Videos

Last Updated: Jun 6, 2026

TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
09:51

TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples

Published on: September 19, 2025

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
05:35

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography

Published on: January 17, 2020

Area of Science:

  • Analytical Chemistry
  • Dental Research
  • Biomaterials Science

Background:

  • Current fluoride analysis techniques lack standardization, leading to inconsistencies in dental research.
  • Variability in methods affects the reliability of fluoride concentration data in biological and non-biological samples.

Purpose of the Study:

  • To develop and recommend standardized analytical methods for fluoride determination.
  • To improve the accuracy and consistency of fluoride measurements in samples relevant to dental research.

Main Methods:

  • Nine laboratories participated in a collaborative study analyzing standardized samples.
  • Existing fluoride analysis techniques were reviewed, inconsistencies identified, and testing conducted.
  • Recommendations were developed for direct and microdiffusion methods using fluoride ion-selective electrodes.

Main Results:

  • Initial analysis showed significant variation in fluoride measurements across laboratories and sample types (saliva, food, beverages).
  • Implementation of standardized methodologies led to precise and accurate fluoride values with reduced inter-laboratory differences.
  • Intraclass correlation coefficients for certified reference materials reached 0.90–0.93 with standardized methods.

Conclusions:

  • Standardized protocols for fluoride (F) analysis are crucial for improving precision and accuracy in dental research.
  • The developed methods significantly decrease inter-laboratory variability, enhancing the reliability of fluoride data.
  • Adoption of these standardized methods will lead to more consistent and trustworthy results in fluoride-related dental studies.