Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
Published on: November 23, 2019
Acetabular anteversion with CT in supine, simulated standing, and sitting positions in a THA patient population
Jean-Yves Lazennec1, Patrick Boyer, Michel Gorin
1Department of Orthopaedic Surgery, La Pitié-Salpétrière Hospital, Assistance Publique-Hopitaux de Paris, 47 bd de l'Hôpital, 75013 Paris, France.
Background:
Appraisal of the orientation of implants in THA dislocations currently is based on imaging done with the patient in the supine position. However, dislocation occurs in standing or sitting positions. Whether measured anteversion differs in images projected in the position of dislocation is unclear.
Questions/Purposes:
We compared measured acetabular cup orientations on axial CT scans taken with the patient in a supine position with those from CT sections at angles to the sacral slope reflecting standing and sitting positions.
Methods:
We retrospectively reviewed the radiographs of 328 asymptomatic patients who had THAs. Anatomic acetabular anteversion (AAA) was measured from the plain CT scan (supine position, axial CT sections). The AAA also was measured on reformatted CT scans in which the orientation was adjusted individually to the sacral slope on lateral radiographs with patients in the standing and sitting positions.
Results:
The mean/(SD) AAA changed from 24.2° (6.9°) in the supine position to 31.7° (5.6°) and 38.8° (5.4°) in simulated standing and sitting positions, respectively. The supine AAA correlated with the standing AAA (r = 0.857) but not with the sitting AAA (r = 0.484).
Conclusions:
These data suggest measurement of the AAA on a plain CT scan used in current practice is biased. In patients with recurrent posterior dislocation from a sitting position, accounting for the functional variations in measurement of the position of the acetabular cup provides more relevant information regarding component positioning.
More Related Videos
07:43In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
Related Concept Videos
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...