Sample Preparation for Probe Electrospray Ionization Mass Spectrometry
Published on: February 19, 2020
On-line electrodialytic salt removal in electrospray ionization mass spectrometry of proteins
Yongjing Chen1, Masanobu Mori, Amanda C Pastusek
1Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, Texas 76019-0065, USA.
Abstract:
Salts and buffers, commonly used in isolation and stabilization of biological analytes, have a deleterious effect on electrospray ionization mass spectrometry (ESI-MS). Excessive concentrations of salts lead to ion suppression and adduct formation, which mask or complicate ion signals. In this work, we describe a salt remover (SR), configured as a three-compartment flow-through system, where the central compartment is separated from the outer compartments by a cation-exchange membrane (CEM) and an anion-exchange membrane (AEM). One platinum electrode is placed in each of the outer compartments, where water or electrolyte is flowing. The CEM electrode is held at a negative potential relative to the AEM side; cations/anions migrate by electrophoresis to the CEM/AEM receiver liquids, respectively. Proteins have poorer electrophoretic mobility relative to the buffer components, permitting removal of the salt. The salt-free proteins proceed to the ESI source. The capillary scale SR (internal volume 2.5 μL) described here effectively desalted continuous flows of NaCl solutions (200 mequiv/L at 1 μL/min, equivalent to a flux of 200 nequiv/min with 88% efficiency) and achieved >99.8% salt removal with 154 mM NaCl (isotonic saline) at 1 μL/min. With optimized current, >80% of concurrently present 20 μM protein was transmitted. Desalting efficiency and analyte loss was evaluated with different salt concentration and flow rate combinations under different applied current. Good-quality ESI-MS spectra of cytochrome c, myoglobin, and lysozyme as test proteins in a saline solution, passed through the SR, are demonstrated.
More Related Videos
10:41Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
10:01Combining Chemical Cross-linking and Mass Spectrometry of Intact Protein Complexes to Study the Architecture of Multi-subunit Protein Assemblies
Published on: November 28, 2017
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...