Luminophore Formation in Various Conformations of Bovine Serum Albumin by Binding of Gold(III)
Published on: August 31, 2018
The interaction between Ag+ and bovine serum albumin: a spectroscopic investigation
Xingchen Zhao1, Rutao Liu, Yue Teng
1Shandong Provincial Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, China–America CRC for Environment & Health, Shandong Province, 27# Shanda South Road, Jinan 250100, PR China.
Abstract:
By using spectroscopic methods, we probed the interaction of Ag(+) with bovine serum albumin (BSA) in an aqueous environment. Fluorescence of BSA quenched by Ag(+) is a dynamic quenching process. Two binding modes-a strong one at low concentration of Ag(+) and a weak one at high concentration were found. The association constant (K(A)) and the number of binding sites (n) were 4.88×10(3)M(-1) and 1.17 for strong binding, and 17.6M(-1) and 0.547 for weak binding at 293K. The results of thermodynamic parameters ΔH(θ), ΔG(θ) and ΔS(θ) for instinct binding modes at different temperatures indicated that the hydrogen bonding and van der Waals interaction play a major role for low Ag(+)/BSA ratio while electrostatic association for high Ag(+)/BSA ratio. Data of UV-Vis and Circular dichroism (CD) suggested that with the increasing amount of Ag(+), the secondary structure undergoes a decrease in α-helix and an increase in β content and the backbone of BSA experiences a micro-environmental alteration. Furthermore, the distance r between donor (Trp-212) and acceptor (Ag(+)) was evaluated to be 10nm according to nonradiative energy transfer theory.
Related Concept Videos
UV–Vis Spectroscopy: Beer–Lambert Law
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in the...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.
Spectroscopy of Carboxylic Acid Derivatives
In the...