Related Experiment Video
Updated: Jun 5, 2026

Synthesis of High Purity Nonsymmetric Dialkylphosphinic Acid Extractants
Published on: October 19, 2017
Automatic twin vessel recrystallizer. Effective purification of acetaminophen by successive automatic
1Department of Molecular Structure Analysis, Tohoku Pharmaceutical University, 4-4-1, Komatsushima, Aobaku, Sendai, Miyagi, 981-0905, Japan. osamnara@tohoku-pharm.ac.jp
Abstract:
I describe an interchangeable twin vessel (J, N) automatic glass recrystallizer that eliminates the time-consuming recovery and recycling of crystals for repeated recrystallization. The sample goes in the dissolution vessel J containing a magnetic stir-bar K; J is clamped to the upper joint H of recrystallizer body D. Empty crystallization vessel N is clamped to the lower joint M. Pure solvent is delivered to the dissolution vessel and the crystallization vessel via the head of the condenser A. Crystallization vessel is heated (P). The dissolution reservoir is stirred and heated by the solvent vapor (F). Continuous outflow of filtrate E out of J keeps N at a stable boiling temperature. This results in efficient dissolution, evaporation and separation of pure crystals Q. Pure solvent in the dissolution reservoir is recovered by suction. Empty dissolution and crystallization vessels are detached. Stirrer magnet is transferred to the crystallization vessel and the role of the vessels are then reversed. Evacuating mother liquor out of the upper twin vessel, the apparatus unit is ready for the next automatic recrystallization by refilling twin vessels with pure solvent. We show successive automatic recrystallization of acetaminophen from diethyl ether obtaining acetaminophen of higher melting temperatures than USP and JP reference standards by 8× automatic recrystallization, 96% yield at each stage. Also, I demonstrate a novel approach to the determination of absolute purity by combining the successive automatic recrystallization with differential scanning calorimetry (DSC) measurement requiring no reference standards. This involves the measurement of the criterial melting temperature T(0) corresponding to the 100% pure material and quantitative ΔT in DSC based on the van't Hoff law of melting point depression. The purity of six commercial acetaminophen samples and reference standards and an eight times recrystallized product evaluated were 98.8 mol%, 97.9 mol%, 99.1 mol%, 98.3 mol%, 98.4 mol%, 98.5 mol% and 99.3 mol% respectively.
More Related Videos
10:33Development of Inhibitors of Protein-protein Interactions through REPLACE: Application to the Design and Development Non-ATP Competitive CDK Inhibitors
Published on: October 26, 2015
06:35Construction and Systematical Symmetric Studies of a Series of Supramolecular Clusters with Binary or Ternary Ammonium Triphenylacetates
Published on: February 15, 2016
Related Concept Videos
Recrystallization: Solid–Solution Equilibria
Downstream Processing
Washing, Drying, and Ignition of Precipitates
Precipitation Processes