The role of pacemaker in hypersensitive carotid sinus syndrome
Ricardo Lopes1, Alexandra Gonçalves, Júlio Campos
1Department of Cardiology, Hospital de São João, E.P.E, Serviço de Cardiologia, Alameda Prof. Hernâni Monteiro, 4200-319 Porto, Portugal. rjlclopes@hotmail.com
Aims:
About 15% of patients with the hypersensitive carotid sinus syndrome (CSS) have no clinical improvement after permanent pacemaker implantation. We aimed to assess the outcome of patients with CSS treated with pacemaker and to determine predictors of symptoms' recurrence.
Methods And Results:
A retrospective analysis of 138 patients in whom pacemaker was implanted for CSS was carried out from February 1990 to October 2008. Data were collected from clinical records. Mean age was 69 ± 10.7 years and 104 patients (75.4%) were men. Mean follow-up period was 4.9 ± 4.4 years. Twenty-one (15.2%) patients presented mixed CSS and 117 (84.8%) cardioinhibitory CSS. The head-up tilt test (HUTT) was performed in 93 patients (67.4%). After pacemaker implantation, 115 (83.3%) patients had no further symptoms, 8 (5.8%) presented minor symptoms and in 15 (10.9%), the symptoms remained unchanged. Among patients with symptoms' recurrence, 8 (38.1%) had mixed CSS and 15 (12.8%) cardioinhibitory CSS. Mixed CSS was the only independent predictor of symptoms' recurrence in total population {hazard ratio (HR) 2.84 [95% confidence intervals (CI) 1.20-6.71]; P = 0.017} and in patients who performed HUTT [HR 1.84 (95% CI 1.01-3.35); P = 0.045]. Although the HUTT result was not related to symptoms' recurrence, patients with mixed CSS were more likely to present a vasodepressor response (61.9 vs. 19.4%; P < 0.001) and a reproduction of spontaneous symptoms (28.6 vs. 2.8%; P = 0,001) on HUTT.
Conclusions:
Permanent pacemaker is an effective treatment for CSS. However, the recurrence of symptoms was two- to three-fold more frequent in patients with mixed CSS, probably due to the persistence of vasodepressor component.
More Related Videos
08:52Generation of Murine Cardiac Pacemaker Cell Aggregates Based on ES-Cell-Programming in Combination with Myh6-Promoter-Selection
Published on: February 17, 2015
07:12Studying the Coding Profiles of Somatic Stimulation on Cardiac-locked Neuronal Responses in the Rat Spinal Dorsal Horn
Published on: May 23, 2025
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism, and...
Electrophysiology of Normal Cardiac Rhythm
Cardiomyopathy III: Hypertrophic Cardiomyopathy
The Parasympathetic Nervous System