Related Experiment Video
Updated: Jun 5, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Indoor radon survey in a university campus of Nigeria
R I Obed1, H T Lateef, A K Ademola
1Department of Physics, University of Ibadan, Nigeria.
Abstract:
CR-39 tracketch detectors were used for the measurement of (222)Rn concentration in 24 offices in Nigeria's oldest university campus in order to estimate the effective dose to the occupants from (222)Rn and its progeny. The dosimetric measurements were made over a period of 3 months. Questionnaires were distributed and analyzed. The radon concentration ranged from 157 to 495 Bq/m(3), with an arithmetic mean and standard deviation of 293.3 and 79.6 Bq/ m(3), respectively. The effective dose to the workers was estimated and this varied from 0.99 to 3.12 mSv/ y, with a mean of 1.85 mSv/y. The radon concentrations were found to be within the reference levels of ICRP.