Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Bending of Members Made of Several Materials01:11

Bending of Members Made of Several Materials

In analyzing a structural member composed of two different materials with identical cross-sectional areas, it is crucial to understand how their distinct elastic properties affect the member's response under load. The analysis involves assessing stress and strain distributions using the transformed section concept, which accounts for variations in material properties.
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Stresses under Combined Loadings01:23

Stresses under Combined Loadings

When analyzing a bent tube with a circular cross-section subjected to multiple forces, it is crucial to determine the stress distribution in order to maintain structural integrity under varied load conditions.
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity01:15

Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity

Deformation occurs in axial and transverse directions when an axial load is applied to a slender bar. This deformation impacts the cubic element within the bar, transforming it into either a rectangular parallelepiped or a rhombus, contingent on its orientation. This transformation process induces shearing strain. Axial loading elicits both shearing and normal strains. Applying an axial load instigates equal normal and shearing stresses on elements oriented at a 45° angle to the load axis.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Reconfigurable Inflatables Through Controlled Surface Crumpling.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

Variability in knee pivoting behavior and condylar translation: Insights from a dynamic CT study.

The Knee·2026
Same author

Influence of bone stress relaxation and abrasion on micromotions in uncemented femoral knee implants: a finite element study.

Medical engineering & physics·2026
Same author

Squeaking at soft-rigid frictional interfaces.

Nature·2026
Same author

Detection of simulated complications in all-polymer PEEK knee prostheses: a cadaveric imaging study using Radiography, CT, and MRI.

Journal of orthopaedic surgery and research·2026
Same author

Neural network surrogates for musculoskeletal models: An application to implant alignment in total knee arthroplasty.

Journal of biomechanics·2026

Related Experiment Video

Updated: Jun 5, 2026

Comprehensive Characterization of Tissue Mineralization in an Ex Vivo Model
07:29

Comprehensive Characterization of Tissue Mineralization in an Ex Vivo Model

Published on: September 27, 2024

Mixed-mode loading of the cement-bone interface: a finite element study.

Daan Waanders1, Dennis Janssen, Katia Bertoldi

  • 1Orthopaedic Research Laboratory, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands. d.waanders@orthop.umcn.nl

Computer Methods in Biomechanics and Biomedical Engineering
|December 21, 2010
PubMed
Summary

This study models the cement-bone interface in hip reconstructions, revealing that shear loading surprisingly generates compression, not failure. These findings offer insights for improved interface modeling and cohesive law development.

More Related Videos

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
07:09

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint

Published on: March 7, 2014

A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
11:28

A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials

Published on: May 18, 2015

Related Experiment Videos

Last Updated: Jun 5, 2026

Comprehensive Characterization of Tissue Mineralization in an Ex Vivo Model
07:29

Comprehensive Characterization of Tissue Mineralization in an Ex Vivo Model

Published on: September 27, 2024

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
07:09

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint

Published on: March 7, 2014

A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
11:28

A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials

Published on: May 18, 2015

Area of Science:

  • Biomaterials Engineering
  • Orthopedic Biomechanics
  • Computational Solid Mechanics

Background:

  • Accurate modeling of the cement-bone interface is critical for understanding cemented hip reconstruction performance.
  • Current models often oversimplify the complex mechanical behavior at this interface.
  • The microstructure of the cement-bone interface significantly influences its mechanical response.

Purpose of the Study:

  • To investigate the mechanical mixed-mode response of the cement-bone interface, considering its microstructure.
  • To develop and validate finite element models of the cement-bone interface.
  • To provide a basis for developing a cohesive law for the cement-bone interface.

Main Methods:

  • Computed tomography (CT)-based plain strain finite element analysis (FEA) models were created.
  • Models incorporated the distinct microstructure of the cement-bone interface.
  • Analyses included periodic boundary conditions and cracking of cement and bone components.

Main Results:

  • FEA results showed favorable comparison with experimental observations.
  • Under shear loading, no interface failure was observed; significant normal compression was generated, preventing dilation.
  • Detailed reaction forces, crack patterns, and stress fields provided insight into mixed-mode failure.

Conclusions:

  • The study provides a more realistic mechanical analysis of the cement-bone interface.
  • The findings challenge previous assumptions about shear loading at the interface.
  • The detailed interface analysis can inform the development of advanced cohesive laws for improved simulation of hip reconstructions.