Related Experiment Video
Updated: Jun 5, 2026

An Economical and Versatile High-Throughput Protein Purification System Using a Multi-Column Plate Adapter
Published on: May 21, 2021
Optimization of peptide and protein separation with a monolithic reversed-phase column and application to
Anne-Christine Schmidt1, Kathleen Mickein
1Technical University Bergakademie Freiberg, Institute of Analytical Chemistry, Leipziger Straße 29, D-09599 Freiberg, Germany. Anne-Christine.Schmidt@chemie.tu-freiberg.de
Abstract:
A separation method for a mixture of eight sulfur-containing peptides and proteins characterized by a wide molar mass (1-18.4 kDa) and pI range (4.5-10.7) was developed onto a monolithic phenyl phase. Based on the first optimization steps that revealed an increase of the acetonitrile content to 45 vol.% as sufficient for the elution of all biomolecules and the addition of the ion pairing reagent trichloroacetic acid (TCA) as preferable over the eluent additives formic acid or ammonium acetate buffer, the critical variables TCA concentration, gradient time, and eluent flow rate were optimized using a Box-Behnken experimental design. To achieve optimum values for separation factors of all peak pairs, a TCA content of 0.025% (m/v), a gradient time of 10 min, and a flow rate of 3.5 mL min(-1) were selected. Arsenic binding studies were undertaken under conditions optimized with respect to the crucial separation factor of the nonapeptides vasotocin (Vtc) and vasopressin (Vpr) in a shortened gradient time of 7.5 min. A complete separation of phenylarsenic-substituted and unmodified forms of these peptides allowed the calculation of both consumptions and apparent equilibrium constants K from HPLC-UV peak areas. The nonapeptide consumptions by the reaction with phenylarsine oxide (PAO) increased from 7% up to 100% in dependence on the molar ratio of the reaction components. Due to an enhanced UV absorption of the phenylarsenic-substituted biomolecules, the calculation of apparent equilibrium constants led to increasing K values with rising PAO molarities from 9.6×10(5) to 1.2×10(8) in case of Vtc and from 2.2×10(6) to 1.4×10(9) in case of Vpr. For α-lactalbumin, a consumption of 59.2±6.1% by the reaction with molar excesses of PAO varying from 1.4 to 21 can be derived from the chromatograms. The quantitative evaluation of the reaction of the small protein aprotinin with PAO was hindered by a pronounced peak broadening that occurred after reduction of the disulfide bridges.
Related Concept Videos
Ion-Exchange Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Affinity Chromatography
Principles Of Column Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...