Internal standards: a source of analytical bias for volatile organic analyte determinations
1U.S. Environmental Protection Agency, National Exposure Research Laboratory, Environmental Sciences Division, P.O. Box 93478, Las Vegas, NV 89193-3478, USA. hiatt.mike@epa.gov
Abstract:
The use of internal standards in the determination of volatile organic compounds as described in SW-846 Method 8260C introduces a potential for bias in results once the internal standards (ISTDs) are added to a sample for analysis. The bias is relative to the dissimilarity between the analyte and internal standard physical properties that influence how easily analytes are separated from a matrix and concentrated during analysis. Method 5032 is a vacuum distillation procedure for extracting analytes from a sample for use with Method 8260C. Vacuum distillation is also incorporated within another GC/MS analytical procedure, Method 8261A. Method 8260C/5032 and Method 8261A are experimentally identical, however, Method 8261A uses internal standards differently by relating the recovery of each compound to its boiling point and relative volatility. By processing each analysis (water, soil, and biota) using both Method 8260C and Method 8261A, the two approaches are compared on the basis of analyte bias and the failure rate of the quality controls. Analytes were grouped by how similar their boiling points and natural log of their relative volatilities (lnRVs) were to their Method 8260C recommended ISTDs. For the most similar analytes, the Method 8260C determinations yielded an average bias less than 10% and a failure to meet calibration criteria less than 7%. However, as the difference between analyte and ISTD became greater the bias increased to over 40% (matrix dependent) and its calibration failure rate approached 70%. In comparison, when the Method 8260C data were reprocessed as Method 8261A determinations, this trend for groupings was minimized with biases increasing from 6% to only 20% and the calibration failure rate went from 0% to 15%.
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Volatilization
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Data Validation
Key parameters for method validation include:
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...