EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. Part III. Virus Detection by RT-qPCR
Published on: January 16, 2016
Simultaneous detection of enteroviruses from surface waters by real-time RT-PCR with universal primers
Chongmiao Zhang1, Xiaochang Wang, Yongjun Liu
1Key Laboratory of Northwest Water Resource, Ecology and Environment, Ministry of Education, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China. zhangchongmiao@yahoo.com.cn
Abstract:
In order to realize simultaneous quantitative detection of various enteroviruses from water samples, a real-time reverse transcription-polymerase chain reaction (real-time RT-PCR) method was developed with universal primer pairs designed based on the highly conserved non-coding region sequences of genome targeting poliovirus, coxsackievirus and enterovirus 71. The recombinant plasmid was constructed as enterovirus DNA standard by cloning poliovirus cDNA into a pMD18-T vector. The real-time RT-PCR method utilizing SYBR Green I was optimized. As a result of a series of examinations, the detection limit of the method was found to be 2.31 genome equivalent copy (GEC)/microL, the intra- and inter-assay variations were lower than 2% and 5%, respectively, and enteroviruses were well distinguished from other microorganisms. There was a good linear relationship (r2 = 0.997) between the logarithm of viral density and cycle threshold in a wide range of 2.31 x 10(0) to 2.31 x 10(9) GEC/microL. The validity of the method was further proved by its application for the detection of enteroviruses from various practical water samples.