Related Experiment Video
Updated: Jun 5, 2026

Anaerobic Protein Purification and Kinetic Analysis via Oxygen Electrode for Studying DesB Dioxygenase Activity and Inhibition
Published on: October 3, 2018
Construction of STOX oxygen sensors and their application for determination of O2 concentrations in oxygen minimum
Niels Peter Revsbech1, Bo Thamdrup, Tage Dalsgaard
1Department of Biological Sciences, Microbiology, Aarhus University, Aarhus, Denmark.
Abstract:
Until recently, it has not been possible to measure O(2) concentrations in oxygen minimum zones (OMZs) with sufficient detection limits and accuracy to determine whether OMZs are anoxic or contain 1-2 μM O(2). With the introduction of the STOX (switchable trace oxygen) sensor, the level for accurate quantification has been lowered by a factor of 1000. By analysis with STOX sensors, O(2) can be prevented from reaching the sensing cathode by another cathode (front guard cathode), and it is the amplitude in signal by polarization/depolarization of this front guard that is used as a measure of the O(2) concentration. The STOX sensors can be used in situ, most conveniently connected to a conventional CTD (conductivity, temperature, and depth analyzer) along with a conventional oxygen sensor, and they can be used for monitoring O(2) dynamics during laboratory incubations of low-O(2) media such as OMZ water. The limiting factors for use of the STOX sensors are a relatively slow response, with measuring cycle of at least 30 s with the current design, and fragility. With improved procedures for construction, the time for a complete measuring cycle is expected to come down to about 10 s.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Amperometry: Overview
Oxygen Requirements and Growth Patterns
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...

