Quantitative analysis of Hb Bart's in cord blood by capillary electrophoresis system

Thongperm Munkongdee1, Dalad Pichanun, Punnee Butthep

  • 1Thalassemia Research Center, Institute of Molecular Biosciences, Mahidol University, Thailand.

Annals of Hematology
|December 29, 2010
PubMed

It has long been recognized that the presence of hemoglobin (Hb) Bart's in newborn's blood is associated with α-thalassemia. However, the automated high-performance liquid chromatography or low-performance liquid chromatography system is unable to quantify the amount of Hbs Bart's and H, which are eluted at the retention time close to 0 min. This study used automatic capillary electrophoresis (CE) system to diagnose various types of α-thalassemia in 587 cord blood samples, including 429 normal α-globin genotype, 120 cases of thalassemia with one α-globin gene defect, 34 cases with two α-globin genes defect, and four cases with three α-globin genes defect. The result showed that the level of Hb Bart's in cord blood was increased accordingly with the increasing numbers of the defective α-globin genes. In addition, Hb Bart's level at 0.2%, as measured by CE, can be used as a cut-off point for α-thalassemia diagnosis in newborns.

Related Concept Videos

Electrophoresis: Overview01:20

Electrophoresis: Overview

Electrophoresis is a powerful analytical separation technique that relies on the differential migration of charged species when subjected to an electric field. The core strength of electrophoresis lies in its ability to separate high-molecular-weight species in complex mixtures. It has found widespread use in biochemistry, molecular biology, and analytical chemistry, allowing the separation of compounds like amino acids, nucleotides, carbohydrates, and proteins with excellent resolution.
There...
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...