Related Experiment Video
Updated: Jun 5, 2026

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Findings of a mixed transfemoral aortic valve implantation program using Edwards and CoreValve devices
Rosa Ana Hernández-Antolín1, Eulogio García, Santiago Sandoval
1Servicio de Cardiología, Instituto Cardiovascular, Hospital Clínico San Carlos, Madrid, Spain. rhernandez_antolin@hotmail.com
Introduction And Objectives:
Transfemoral implantation of an Edwards SAPIEN (ES) or Medtronic CoreValve (MCV) aortic valve prosthesis is an alternative to surgical replacement for patients with severe aortic stenosis and a high surgical risk. The study's aim was to compare results obtained with these two devices.
Methods:
Prospective observational study of transfemoral prosthesis implantation performed at our center.
Results:
Of the 76 patients (age 83 ± 6 years, 63% female, logistic EuroSCORE 18 ± 9) included, 50 were assigned the ES and 26 the MCV device. There was no difference between the groups in age, sex, functional class, valve area, associated conditions, or EuroSCORE. Implantation was successful in 84% of the ES group and 100% of the MCV group (P = .04). There were three cases of tamponade, two aortic dissections and one valve malposition in the ES group. The two groups had similar vascular access complication rates (26% vs. 23%; P=NS), but pacemaker need was greater with the MCV (10% vs. 39%; P = .003). Mortality rates at 30 days were 12% and 20% (P = NS) in the ES and MCV groups, respectively, and at 1 year, 24% and 20% (P = NS), respectively. After a follow-up of 367 ± 266 days in the ES group and 172 ± 159 days in the MCV group, three patients died. Clinical improvement was maintained in other patients and no echocardiographic changes were observed.
Conclusions:
In-hospital mortality, the complication rate and medium-term outcomes were similar with the two devices. The only difference observed was a higher implantation success rate with the MCV, although at the expense of a greater frequency of atrioventricular block.
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis I: Introduction
Aortic Regurgitation III: Medical Management
