Related Experiment Video
Updated: May 7, 2026

Detection of a Circulating MicroRNA Custom Panel in Patients with Metastatic Colorectal Cancer
Published on: March 14, 2019
High sensitivity of five colorectal screening programmes with faecal immunochemical test in the Veneto Region, Italy
Manuel Zorzi1, Chiara Fedato, Grazia Grazzini
1Veneto Tumour Registry, Istituto Oncologico Veneto IRCCS, P.ggio Gaudenzio, 1, 35132 Padua, Italy. manuel.zorzi@ioveneto.it
Objective:
Although guaiac-based faecal occult blood test screening has been shown to be effective in reducing colorectal cancer (CRC) mortality, it has been criticised mostly for its low sensitivity. Italian CRC screening programmes are based on immunochemical tests (iFOBT). We collected and analysed the interval cancers (ICs) found by five screening programmes to estimate their sensitivity.
Methods:
ICs were identified in subjects who had a negative result in a screening examination from 2002 to 2007 (N=267,789); data were linked with 2002-2008 hospital discharge records. Analysis was based on the follow up of 468,306 person-years. The proportional incidence-based sensitivity was estimated overall and by sex, age class, time since last negative iFOBT result, anatomical site, and history of screening (first or subsequent test).
Results:
Overall, 126 ICs were identified, compared to 572 expected cancers. The proportional incidences were 15.3% and 31.0% in the first and the second interval-years, respectively, with an overall episode sensitivity of 78.0% (95% CI: 73.8 to 81.6). Sensitivity was higher for males than females (80.1% vs 74.8%); no differences were observed by age, anatomical site or between programmes. The test sensitivity of iFOBT was 82.1% (95% CI 78.1% to 85.3%).
Conclusions:
iFOBT-based screening programmes showed a high performance in terms of sensitivity as estimated through the IC rates. The screening schedule utilised in our programmes (single iFOBT, positivity threshold of 100 ng Hb/ml of sample solution, inter-screening interval of 2 years) shows low rates of missed cancers that are diagnosed during the interval. HDR are a convenient and reliable source of data for IC studies.
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Serum Laboratory Studies, Stool Test, Breath Test
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...

