Related Experiment Video
Updated: Jun 5, 2026

Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Patient demographics, complications, and hospital utilization in 250 consecutive device implants in a new community
Jeffrey L Williams1, David Lugg, Robert Gray
1Clinical Cardiac Electrophysiology, The Good Samaritan Health System, Lebanon Cardiology Associates, Lebanon, PA 17042, USA. lcaep@hotmail.com
Background:
Single-center reports on patient demographics and early (<6 weeks) device complication rates in academic hospitals are scant and non-existent for non-academic community hospital electrophysiology (EP) programs.
Objective:
The objective of our study was to examine the demographics, complications, re-admissions, and accessibility of care in a community EP program to add to the body of knowledge of 'real-world' defibrillator implant complications.
Methods:
Two hundred and fifty consecutive patients who underwent device implantation by a single electrophysiologist in a new non-academic community hospital EP program starting from its inception in July 2008 were included for analysis. Standard procedures for implantation were used. Pacemakers, defibrillators, and generator changes were included; temporary pacemakers were excluded. Major complications were defined as in-hospital death, cardiac arrest, cardiac perforation, cardiac valve injury, coronary venous dissection, hemothorax, pneumothorax, transient ischemic attack, stroke, myocardial infarction, pericardial tamponade, and arteriovenous fistula. Minor complications were defined as drug reaction, conduction block, hematoma or lead dislodgement requiring re-operation, peripheral embolus, phlebitis, peripheral nerve injury, and device-related infection.
Results:
This community cohort had similar ejection fractions but was older with worse kidney function than those studied in prior reports. There was one major early complication (0.4%) and seven minor early complications (2.8%). Left ventricular lead placement was successful in 64 of 66 patients (97%).
Conclusions:
This is the first community-hospital-based EP program to examine device implant demographics and outcomes, and revealed an elderly, ill population with lower overall rates of complications than seen in national trials and available reports from single non-community centers. Contrary to current perceptions, these data suggest that community centers may subselect an elderly, ill patient population and can provide high-quality, cost-effective, and more accessible care.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
06:29Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Cardiomyopathy V: Interprofessional Care
Cardiac Catheterization IV: Nursing Management
Holter Monitor: 24-Hour Monitoring