Related Experiment Video
Updated: Jun 5, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Aortic and hepatic enhancement at multidetector CT: evaluation of optimal iodine dose determined by lean body weight
Hiroshi Kondo1, Masayuki Kanematsu, Satoshi Goshima
1Department of Radiology, Gifu University Hospital, 1-1 Yanagido, 501-1194 Gifu, Japan. hkondo@gifu-u.ac.jp
Purpose:
To determine the optimal iodine dose for aortic and hepatic enhancement at MDCT by comparing lean body weight (LBW) with total body weight (TBW).
Materials And Methods:
This study was approved by our institutional review committee. One hundred and thirty-six patients were randomized into four groups: 550, 650, 750 mg iodine/(kg of LBW) and 600 mgI/(kg of TBW). The aortic and hepatic contrast enhancements (Δ HUs) during the portal venous-phase and variances of ΔHUs were compared.
Results:
Mean ΔHUs for 550, 650, 750 mgI/kg LBW and 600 mgI/kg TBW were: 95.1, 109.9, 122.4, and 131.2HU, respectively, for the aorta. For the liver, 43.1, 55.4, 60.8, and 63.5 HU. Mean Δ HUs increased with iodine dose per kg LBW (p<0.01), but no significant difference between 750 mgI/kg LBW and 600 mgI/kg TBW groups. Hepatic enhancement increased by ≥50 HU in 94% of patients with 750 mg/kg LBW. Variance of hepatic enhancement was marginally greater in the 600 mgI/kg TBW than in the 550 and 750 mgI/kg LBW.
Conclusion:
Hepatic enhancement variation was reduced with iodine doses based on LBW. Iodine dose of 750 mg iodine/kg LBW was appropriate to achieve hepatic enhancement≥50 HU in 94% of patients.
More Related Videos
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...