Non-contrast computed tomography is comparable to contrast-enhanced computed tomography for aortic volume analysis
P Nambi1, R Sengupta, Z Krajcer
1Department of Radiology, Texas Heart Institute at St. Luke's Episcopal Hospital, Houston, TX 77030, USA.
Objectives:
To evaluate whether non-contrast computed tomography (NCCT) images are as reliable as contrast-enhanced computed tomography (CECT) images for the measurement of aortic volume (AV).
Materials And Methods:
A total of 316 pairs of AVs were retrospectively measured from 316 consecutive patients, who underwent endovascular aneurysm repair (EVAR). A standardised multidetector computed tomography protocol was used to obtain precontrast, arterial and delay-phase images. A single blinded, experienced observer measured the AV from the lowest renal artery to the aortic bifurcation by means of the disc-summation method, using the precontrast and arterial-phase images. A second blinded observer measured the AV again in 16 randomly chosen cases.
Results:
Both NCCT and CECT yielded similar AVs that were highly correlated (r(2) = 0.99; P < 0.0001). Bland and Altman analysis revealed a small bias (mean ± 2 standard deviations: -0.9 ± 8 ml). The intraclass correlation coefficients (all >0.99; P < 0.0001) and low repeatability coefficients indicated that the AVs were reproducible with both methods.
Conclusions:
The AVs measured from NCCT images were accurate and highly reproducible compared with those from CECT images. Therefore, NCCT can be a reasonable alternative to CECT for AV assessment after EVAR. This is particularly important for patients with renal insufficiency (potentially sparing them from nephrotoxic contrast agents and unnecessary radiation) or allergy to contrast agents.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aneurysm III: Interprofessional Care