Objectives:
The aim of this study is to evaluate our clinical experience using an Amplatzer septal occluder for catheter closure of a secundum atrial septal defect under transthoracic echocardiography guidance without general anaesthesia.
Methods:
Patients eligible for transcatheter atrial septal defect closure were selected using transthoracic echocardiography. The largest defect diameter measured in different views was selected as the reference diameter. All procedures were performed under conscious sedation with fluoroscopic and transthoracic echocardiographic guidance.
Results:
Between November, 2006 and December, 2009 a secundum-type atrial septal defect was closed with the Amplatzer septal occluder in 40 patients with transthoracic echocardiographic guidance. The mean age and weight were 7.9 years and 26.9 kilograms, respectively. The mean atrial septal defect diameter was 11.4 millimetres, total septal diameter was 38.5 millimetres, and the mean device diameter and the difference between device and atrial septal defect diameter were 12.6 and 1.2 millimetres, respectively. There were no major complications. The mean follow-up time was 14.8 months.
Conclusion:
In selected cases, in which the defects are small and the rims are adequate and transthoracic echocardiography provides high image quality, transthoracic echocardiography can be substituted with transoesophageal echocardiography. The ratio of defect size to total septal diameter can be used as a guide for patient selection; those that have a value of 0.33 or greater can be considered eligible for closure with transthoracic echocardiography. However, transthoracic echocardiography should not be used when there are large or multiple defects, or the rims are thin and soft and the image resolution is inadequate.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...