Related Experiment Video
Updated: Jun 5, 2026

Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Near infrared spectroscopy-derived interstitial hydrogen ion concentration and tissue oxygen saturation during
Stuart M C Lee1, Mark S F Clarke, Daniel P O'Connor
1NASA Johnson Space Center's Cardiovascular Laboratory, Wyle Integrated Science and Engineering Group, 1290 Hercules Blvd., Houston, TX 77058, USA. stuart.lee-1@nasa.gov
Abstract:
The objective of this study was to determine whether walking and running at different treadmill speeds resulted in different metabolic and cardiovascular responses in the vastus lateralis (VL) and lateral gastrocnemius (LG) by examining metabolite accumulation and tissue oxygen saturation. Ten healthy subjects (6 males, 4 females) completed a submaximal treadmill exercise test, beginning at 3.2 km h(-1) and increasing by 1.6 km h(-1) increments every 3 min until reaching 85% of age-predicted maximal heart rate. Muscle tissue oxygenation (SO(2)), total hemoglobin (HbT) and interstitial hydrogen ion concentration ([H(+)]) were calculated from near infrared spectra collected from VL and LG. The [H(+)] threshold for each muscle was determined using a simultaneous bilinear regression. Muscle and treadmill speed effects were analyzed using a linear mixed model analysis. Paired t-tests were used to test for differences between muscles in the [H(+)] threshold. SO(2) decreased (P = 0.001) during running in the VL and LG, but the SO(2) response across treadmill speeds was different between muscles (P = 0.047). In both muscles, HbT and [H(+)] increased as treadmill speed increased (P < 0.001), but the response to exercise was not different between muscles. The [H(+)] threshold occurred at a lower whole-body VO(2) in the LG (1.22 ± 0.63 L min(-1)) than in the VL (1.46 ± 0.58 L min(-1), P = 0.01). In conclusion, interstitial [H(+)] and SO(2) are aggregate measures of local metabolite production and the cardiovascular response. Inferred from simultaneous SO(2) and [H(+)] measures in the VL and LG muscles, muscle perfusion is well matched to VL and LG work during walking, but not running.
More Related Videos
04:36Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.