The article deals with 140 cardiotocographic curves during opening and 147 curves during expulsion in puerpera in whom delivery was performed under cardiotocography and pH-metry. During different changes of foetal heart frequency pH values of foetal blood were determined. On the basis of cardiotocographic changes the examined group was divided into several subgroups. In each group the mean values of current pH were compared with the mean values of the control group. The control group consisted of 41 cardiotocographic curves during opening and 41 during expulsion in patients with normal delivery and clear foetal liquid. The pH of foetal blood was determined during opening and expulsion. Mean pH values of foetal blood were significantly lower during opening with expressed variable DIP-I and DIP-II as well as with slight and strong bradicardy. During expulsion a significant fall of mean pH values was observed only in the group with expressed variable DIP-I and DIP-II. Consequently the Apgar score of newborn infants was reduced. The mean pH values in other cardiotocographic changes were decreased but statistically insignificant. The same was observed in Apgar score.
The article deals with 140 cardiotocographic curves during opening and 147 curves during expulsion in puerpera in whom delivery was performed under cardiotocography and pH-metry. During different changes of foetal heart frequency pH values of foetal blood were determined. On the basis of cardiotocographic changes the examined group was divided into several subgroups. In each group the mean values of current pH were compared with the mean values of the control group. The control group consisted of 41 cardiotocographic curves during opening and 41 during expulsion in patients with normal delivery and clear foetal liquid. The pH of foetal blood was determined during opening and expulsion. Mean pH values of foetal blood were significantly lower during opening with expressed variable DIP-I and DIP-II as well as with slight and strong bradicardy. During expulsion a significant fall of mean pH values was observed only in the group with expressed variable DIP-I and DIP-II. Consequently the Apgar score of newborn infants was reduced. The mean pH values in other cardiotocographic changes were decreased but statistically insignificant. The same was observed in Apgar score.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...