Related Experiment Video
Updated: Jun 5, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Wireless patient monitoring system for patients with nasal obstruction
Hyuk Choi1, Il-Ho Park, Hu Geun Yoon
1Department of Biomedical Engineering, Brain Korea 21 Project for Biomedical Science, College of Medicine, Korea University, Seoul, Korea.
Abstract:
A new system for nasal sound analysis via Internet to cellular phone was investigated. Spectral analysis of the nasal sound with frequency domain and dB is an important factor in the investigation of nasal airflow pattern. This study included 10 patients and 10 healthy subjects. Patients underwent nasal septoplasty surgery for treatment of nasal septal deviation. This nasal sound analysis was performed on subjects at 1 month postsurgery. This study was performed using an investigator-developed software that sends real-time frequency and spectral analysis video of a patient's nasal sound to an otolaryngologist's cellular phone. Sound intensity was observed at over 25 dB with high range of frequency (2-4 kHz) and less than 10 dB with low (500-1,000 Hz) and medium (1-2 kHz) frequency from 10 patients with nasal obstruction symptoms (group A). In 10 healthy subjects without nasal obstruction symptoms (group B), sound intensity was observed at high frequencies below 5 dB; however, low and medium frequencies were above 15 dB. A statistically significant difference in sound intensity was observed between group A and group B. It was ascertained that use of the new technique will help patients to avoid an unnecessary return to the hospital and will also save money and time.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...